Cable-controlled gas shutoff valve for 2-inch pipe, normally closed with aluminium body, Buna-N seal and 302 stainless steel spring, rated to 150 psig and 132 °F, Cv 54, UL component listed
- TypeDrain Components
- Cable release enables remote emergency shut-off
- Normally closed design blocks flow until activated
- Aluminium body with 302 stainless steel spring resists corrosion
- Buna-N seals rated to 132 °F maximum fluid temperature
- UL Component Listed for safety compliance
Red Hat Gas Shutoff Valve 2 in
The Red Hat HV216585005 is a cable-controlled gas shutoff valve designed for industrial and commercial piping systems. It uses a normally closed 2-way design with an aluminum body and Buna-N seals. The valve requires a cable release to close and is UL Component Listed for safety compliance.
Pressure range and flow capacity
The valve operates from 0 psig minimum up to 150 psig maximum pressure differential. A Cv flow factor of 54 defines its practical flow limit for gas service. Exceeding the 150 psig rating risks seal failure and loss of shutoff function.
Temperature headroom and material limits
Maximum fluid temperature is 132 Degrees F, set by the Buna-N seal and aluminum construction. Internal spring uses 302 stainless steel and tube uses 305 stainless steel for corrosion resistance. Above 132 Degrees F the seal material degrades and the valve cannot maintain reliable closure.
Highlights
- Cable release enables remote emergency shut-off
- Normally closed design blocks flow until activated
- Aluminium body with 302 stainless steel spring resists corrosion
- Buna-N seals rated to 132 °F maximum fluid temperature
- UL Component Listed for safety compliance
Specifications
| Type | Drain Components |
|---|---|
| Brand | Red Hat |
| Model | HV216585005 |
Questions about this item
Should I choose the 2-inch version or a different pipe size for my gas line?
This valve is built for a 2-inch pipe size with a Cv flow factor of 54, so select it when your piping matches that diameter and flow requirement.
What does the 150 psig maximum pressure differential mean once the valve is installed?
It indicates the valve can safely operate with up to 150 psig pressure difference across the inlet and outlet while maintaining reliable shutoff.
How does the cable-release control method affect daily operation of this shutoff valve?
The cable-release mechanism lets you close the normally closed valve remotely by pulling the cable, providing manual emergency shutoff without electrical power.