Red Hat ASCO 8210G002V Solenoid Valve 1/2 in Pipe
Pilot-operated, normally closed solenoid valve controls air, inert gases, light oil and water with a brass body, 1/2 inch NPTF connections, 120 V AC coil and IP66 enclosure
- TypeOther
- Controls air, inert gas, light oil and water
- Pilot-operated, normally closed, brass body
- IP66-rated enclosure for indoor or outdoor use
- 120 V AC coil, 6.1 W, Class F insulation
- Max pressure 200 psi air, 135 psi oil, 150 psi water
Industrial fluid control
The ASCO 8210G002V is a pilot-operated solenoid valve built for controlling air, inert gases, light oil and water in industrial and commercial systems. Its normally closed, 2-way design opens when energised at 120V AC and closes automatically when power is removed. The brass body and FKM seals handle fluid temperatures up to 180°F and ambient conditions from 14°F to 140°F.
Coil and sealing included
The valve ships with its 6.1 W Class F coil and sealing components already assembled, so no separate coil purchase or seal kit is required. An IP66-rated enclosure protects the coil from dust and powerful water jets, making the unit suitable for indoor and outdoor mounting. A 1/2 in conduit hub provides the electrical entry point; a junction box is not supplied.
Brass body with NPTF threads
The 1/2 in NPTF inlet and outlet connect directly to standard piping without adapters. Maximum operating pressure differentials are 200 psi for air and inert gas, 135 psi for light oil and 150 psi for water. The valve must be mounted vertically with the coil upright. Overall dimensions are 3 in long, 3-15/16 in high and 2-5/16 in wide, with a centre-line pipe height of 2-13/16 in.
Highlights
- Controls air, inert gas, light oil and water
- Pilot-operated, normally closed, brass body
- IP66-rated enclosure for indoor or outdoor use
- 120 V AC coil, 6.1 W, Class F insulation
- Max pressure 200 psi air, 135 psi oil, 150 psi water
Specifications
| Brand | ASCO |
|---|---|
| Type | Other |
Questions about this item
How often should the FKM seals in the 8210G002V be inspected or replaced under normal service?
FKM seals resist oil, water and inert gas up to 180 °F fluid temperature; plan inspection annually and replace if leakage appears at the 1/2 in NPTF ports.
What pressure limit will be reached first during continuous operation with compressed air?
The maximum operating pressure differential for air or inert gas is 200 psi, so that ceiling appears before the 135 psi oil or 150 psi water ratings.
How much heat does the 6.1 W coil generate when the valve stays energised all day in a 140 °F ambient environment?
The Class F coil dissipates 6.1 W continuously; in a 140 °F ambient the enclosure surface will rise above ambient but remains within the IP66-rated thermal limits.