Red Hat
Red Hat 8263H305 Solenoid Valve Trap 3/8 in 110/120V AC
A 2-way normally-closed solenoid valve with a 3/8 inch brass body, PTFE seals and a 0.52 Cv rating for 110/120V AC operation
- TypeDrain Components
- Compact 2-way valve simplifies piping layout
- Normally closed design prevents flow until energised
- Brass body with PTFE seals resists corrosion
- 52 Cv rating delivers precise flow control
- Operates on 110/120V AC for standard supply
Solenoid Valve for Fluid Control
The Red Hat 8263H305 is a 2-way, normally closed solenoid valve designed to manage air or inert gas flow in plumbing and industrial systems. Its brass body and PTFE seals suit general-purpose fluid handling where a compact, reliable shut-off device is required.
Suits Automated Shut-Off Needs
This valve fits installations that need electrically actuated on-off control with a 3/8 inch pipe connection and a 5/32 inch orifice. It is not for applications requiring fuel gas or fuel oil service, higher pressure differentials than the 0.52 Cv rating supports, or a coil enclosure with an integrated junction box.
Verify Voltage and Pressure Compatibility
Confirm the supply voltage matches the 110V AC or 120V AC coil rating before wiring. Check that the system operating pressure stays within the valve's air and inert gas limits, and ensure the 3/8 inch pipe threads match the existing piping.
Highlights
- Compact 2-way valve simplifies piping layout
- Normally closed design prevents flow until energised
- Brass body with PTFE seals resists corrosion
- 52 Cv rating delivers precise flow control
- Operates on 110/120V AC for standard supply
Specifications
| Type | Drain Components |
|---|---|
| Brand | Red Hat |
| Model | 8263H305 |
Questions about this item
What pipe fitting do I need to connect the 3/8 in nominal pipe size?
The valve has a 3/8 in nominal pipe size so you must already have matching 3/8 in NPT pipe or fittings to thread it into the system.
Will the brass body and PTFE seal handle the same fluids as my older steel valve?
The body is brass with a PTFE seal rated for air, inert gas and fuel oil; verify your existing fluid is compatible with those materials before reusing the same line.
How can I confirm the coil is energised on 110/120V AC after wiring?
With power applied the normally closed valve should open; listen for the solenoid click and check that flow begins through the 5/32 in orifice at the rated .52 Cv.
Also in this aisle