Red Hat
Red Hat 8222G070 1/4 in Brass Steam Solenoid Valve Trap
Controls steam flow with a 1/4 in brass body, normally closed operation, PTFE seals and a 1.2 Cv rating at 110 or 120 V AC
- TypeDrain Components
- MaterialHAWA
- Reliable steam control with normally closed operation
- Brass body and PTFE seal resist high-temperature corrosion
- 2 Cv flow coefficient handles demanding applications
- Watertight coil enclosure protects electrical components
- 110V AC and 120V AC compatibility simplifies installation
Brass Steam Solenoid Valve
The Red Hat 8222G070 is a normally closed 2-way solenoid valve built for steam service. It has a brass body with PTFE seals and a 3/8 in orifice rated at Cv 1.2. The watertight coil enclosure accepts 110V AC or 120V AC supply.
Industrial Steam Line Control
This valve suits process lines that need reliable on-off control of steam at the stated pressures. It is not for fuel gas or fuel oil circuits because those pressure ratings are not applicable. Air and inert gas maximum differential is not rated so designers must verify suitability.
1/4 in Nominal Pipe Size
The nominal pipe size of 1/4 in determines whether this valve fits the existing piping. Confirm the connection size before ordering because no other port option exists for this model.
Highlights
- Reliable steam control with normally closed operation
- Brass body and PTFE seal resist high-temperature corrosion
- 2 Cv flow coefficient handles demanding applications
- Watertight coil enclosure protects electrical components
- 110V AC and 120V AC compatibility simplifies installation
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Red Hat |
| Model | 8222G070 |
Questions about this item
Which nominal pipe size and orifice combination should I select for my steam line?
This valve has a 1/4 in nominal pipe size and a 3/8 in orifice diameter, fixed for this model 8222G070.
What does the Cv of 1.2 tell me about flow through this valve?
A Cv of 1.2 means the valve passes 1.2 US gallons per minute of water at a 1 psi pressure drop; for steam it indicates the relative flow capacity under your system pressure.
How does the 110V AC or 120V AC coil voltage affect installation?
The coil operates on either 110V AC or 120V AC supply, so it connects directly to standard North American control circuits without a transformer.