Red Hat
Red Hat 8222G047 1/2 in Brass Steam Solenoid Trap
1/2 in brass solenoid valve handles steam with a 3.6 Cv flow rating and watertight coil
- TypeDrain Components
- MaterialHAWA
- Normally closed design prevents steam loss when de-energised
- Brass body resists corrosion in high-temperature steam service
- PTFE seal withstands heat without degrading over time
- 6 Cv rating delivers strong flow for 1/2 in piping
- Watertight coil enclosure protects 110/120V AC winding from moisture
Brass Steam Solenoid Valve 1/2 in
This 1/2 in brass solenoid valve controls steam flow in industrial and commercial systems. It operates on 110V AC or 120V AC power with a normally closed configuration. The PTFE seal and watertight coil enclosure suit high-temperature service. The valve provides a Cv of 3.6 for steam applications.
Not for low-pressure air or fuel systems
The valve carries no rated maximum pressure differential for air or inert gas. Fuel gas and fuel oil maximums are listed as not applicable. Buyers needing rated pressure limits for those media should select a different valve. California Proposition 65 warnings also apply for cancer and reproductive harm.
120V AC normally closed steam service
The coil voltage of 120V AC and normally closed starting position define the control logic. This combination suits automated steam shut-off where power loss closes the valve. Verify the supply voltage matches 110V AC or 120V AC before installation.
Highlights
- Normally closed design prevents steam loss when de-energised
- Brass body resists corrosion in high-temperature steam service
- PTFE seal withstands heat without degrading over time
- 6 Cv rating delivers strong flow for 1/2 in piping
- Watertight coil enclosure protects 110/120V AC winding from moisture
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Red Hat |
| Model | 8222G047 |
Questions about this item
What pipe size and orifice diameter does the 8222G047 require for mounting?
The valve uses a 1/2 in nominal pipe size and a matching 1/2 in orifice, so the piping and flange must accommodate that exact diameter.
How is the 120V AC coil wired during installation, and what step is often missed?
Connect the coil leads to a 110–120V AC supply; the step often missed is verifying the coil enclosure remains watertight after wiring to maintain the seal.
Which component will need periodic replacement in steam service?
The PTFE seal is the wear item that will require inspection and eventual replacement as it ages under high-temperature steam cycles.