We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Raritan

Raritan PX2-2288R-N1 208V 24A rack power distribution unit

SKU CH-S7BA-K0APQ

Distributes 208V power at up to 24A across rack-mounted equipment with NEMA L6-30P input and 5kVA capacity

  • 208 V three-phase input powers dense rack loads
  • 24 A rated current sustains continuous 5 kVA capacity
  • NEMA L6-30P plug connects directly to 30 A facility circuits
  • 3 m cord reaches distant power panels without adapters
  • LEGBX66-20 breaker isolates faults to protect downstream gear

Raritan PX2-2288R-N1 208V PDU

The Raritan Dominion PX2-2288R-N1 is a rack-mountable power distribution unit built for 208V environments. It accepts a NEMA L6-30P input plug and delivers a power capacity of 5kVA through a 3m cord. This unit suits data-centre operators who need reliable power distribution for server racks.

Suits 24A continuous loads; not for higher draw

The PDU supports a maximum input current of 30A with a rated continuous current of 24A. Overload protection is provided by an LEGBX66-20 device. Facilities requiring sustained loads above 24A or a different input voltage should evaluate alternative power distribution equipment.

208V nominal input and output voltage

Both the input and output nominal voltage are fixed at 208V. The unit does not convert voltage, so connected equipment must operate at this level. Verify that your rack gear matches this voltage before deployment.

Highlights

  • 208 V three-phase input powers dense rack loads
  • 24 A rated current sustains continuous 5 kVA capacity
  • NEMA L6-30P plug connects directly to 30 A facility circuits
  • 3 m cord reaches distant power panels without adapters
  • LEGBX66-20 breaker isolates faults to protect downstream gear

Specifications

No published specifications for this item yet.

Questions about this item

How much continuous current can the unit supply before its overload protection trips?

The built-in LEGBX66-20 breaker limits sustained draw to 20 A per protected circuit.

What heat or fan noise should be expected when the PDU runs at its 24 A rated load all day?

The unit has no active cooling; it relies on passive airflow, so it adds minimal audible noise but will warm the rack space proportionally to the 5 kVA load.

Which input receptacle must the facility provide for the 3 m cord and NEMA L6-30P plug?

A matching NEMA L6-30R 208 V 30 A outlet is required on the branch circuit feeding the rack.