Qingdao Hantek Electronic Co.,Ltd
Qingdao Hantek Electronic Co.,Ltd DSO2D10 100MHz 2CH 1GSa/s 8M with 1CH 25MHz Waveform Generator
Dual-channel oscilloscope with 100MHz bandwidth, 1GSa/s sampling, 8M memory and built-in 25MHz waveform generator
- 100 MHz bandwidth captures fast signals
- 1 GSa/s sample rate resolves fine detail
- 8 M memory depth stores long captures
- Built-in 25 MHz waveform generator creates test signals
- 32 automatic measurements with statistics speed analysis
Oscilloscope for labs and hobbyists
The Hantek DSO2D10 is a dual-channel digital storage oscilloscope with 100MHz bandwidth and 1GSa/s sample rate. It provides 8M memory depth for extended waveform capture. The instrument targets engineers, students and hobbyists working on embedded systems, communications or general electronic repair.
Built-in generator and protocol tools
A single-channel 25MHz arbitrary waveform generator adds stimulus capability for circuit testing. Fourteen trigger modes and five serial protocol trigger and decode options cover RS232, UART, I2C, SPI, CAN and LIN. Thirty-two automated measurements with statistics, a 3-digit digital voltmeter and 6-digit hardware frequency counter speed up debug sessions.
SCPI control and USB connectivity
Abundant SCPI remote commands allow automated control from a connected laptop. The USB link lets users stream data directly to PC software for documentation or further analysis. The shared motherboard and chipset with the DSO4000 series provide a proven platform for daily bench use.
Highlights
- 100 MHz bandwidth captures fast signals
- 1 GSa/s sample rate resolves fine detail
- 8 M memory depth stores long captures
- Built-in 25 MHz waveform generator creates test signals
- 32 automatic measurements with statistics speed analysis
Specifications
No published specifications for this item yet.
Questions about this item
Will the probes or the built-in waveform generator need periodic recalibration?
The 100 MHz bandwidth and 1 GSa/s sampling rate are factory calibrated; the 1 CH 25 MHz waveform generator and the 2-channel inputs share the same calibration cycle recommended by the manufacturer.
What measurement limit is reached first during long captures at the maximum sample rate?
The 8 M memory depth fills first when both channels run at 1 GSa/s, limiting continuous capture time before the buffer wraps.
How much fan noise and heat appear when the scope runs continuously on the bench?
The unit uses the same motherboard and chip-set as the DSO4000 series, so thermal design and acoustic profile match that established platform.