Pintech
Pintech PT710-H AC/DC current probe 400A 300kHz BNC measurement tool
AC/DC current probe measures up to 400 A peak AC and 200 A DC with 300 kHz bandwidth, BNC output and ±3 % accuracy
- Size/Dimensions280*70*32 mm
- Selling UnitEach
- TypeElectrical Testing & Measuring
- Accuracy±3%
- Standards/CertificationsCE
- Measures AC up to 400 A peak and DC up to 200 A
- Bandwidth reaches 300 kHz with 1.2 µs rise time
- Standard BNC output fits any oscilloscope plus multimeter adapter included
- ±3 % accuracy from 50 mA to 20 A at 100 mV/A
- Jaw opens to 11 mm for conductors up to 300 V CAT III
AC/DC current probe for oscilloscopes
The PT710-H measures AC current up to 400 A peak-to-peak and DC current up to 200 A with a bandwidth of 300 kHz. It connects through a standard BNC interface and includes an adapter for multimeter use. Designed for technicians who need a single clamp for both AC and DC waveforms.
Check your scope input and voltage category
Verify that your oscilloscope accepts a BNC connector and can display the probe’s 10 mV/A or 100 mV/A output scaling. The maximum working voltage is 300 V CAT III and the maximum floating voltage is 600 V CAT II. The jaw opens to 11 mm, so confirm the conductor diameter fits.
Upgrades the earlier PT710-A model
This version extends the measurement range, adds an overload display and improves high-current accuracy to ±15 % at 80–200 A peak on the 10 mV/A range. It suits users who found the previous model’s range too narrow or who need the extra visual warning during long captures.
Highlights
- Measures AC up to 400 A peak and DC up to 200 A
- Bandwidth reaches 300 kHz with 1.2 µs rise time
- Standard BNC output fits any oscilloscope plus multimeter adapter included
- ±3 % accuracy from 50 mA to 20 A at 100 mV/A
- Jaw opens to 11 mm for conductors up to 300 V CAT III
Specifications
| Brand | PINTECH |
|---|---|
| Model | PT710-H |
| Size/Dimensions | 280*70*32 mm |
| Selling Unit | Each |
| Type | Electrical Testing & Measuring |
| Accuracy | ±3% |
| Standards/Certifications | CE |
Questions about this item
What comes in the box and do I need any extra cables or adapters to start measuring?
The package includes the PT710-H probe, a BNC cable, two adapters and a manual. The BNC cable connects directly to any oscilloscope and one adapter lets you plug into a multimeter, so no extra leads are required.
Should I use the 10mV/A or 100mV/A range for my application?
Choose 100mV/A for currents between 50mA and 20A peak (±3% accuracy) and 10mV/A for 500mA to 200A peak; accuracy is ±4% up to 80A and ±15% from 80A to 200A.
What does the 300kHz bandwidth mean when I am measuring a switching power supply?
The probe passes signals from DC to 300kHz with a 1.2s rise time, so it will capture the fundamental and lower harmonics of most switching waveforms but will attenuate faster edges above that frequency.