Pintech
Pintech PT-5260 60kV 60MHz 500X/5000X differential probe measurement tool
A differential probe that converts two-point signals to ground-referenced measurements for oscilloscopes, handling up to 60 kV peak-to-peak with 60 MHz bandwidth
- Selling UnitEach
- TypeOscilloscopes Probe
- Size/Dimensions275*147*34mm
- IncludesProbe Hook x 2, Alligator Clip x 2, BNC cable x 1, Grounding
- Safely measure up to 60 kV peak-to-peak differential signals
- DC to 60 MHz bandwidth at 500× attenuation for fast edges
- ±2 % typical accuracy ensures reliable high-voltage readings
- 500× and 5000× attenuation ratios cover a wide voltage range
- BNC output works with any oscilloscope input
High-voltage differential probe for oscilloscopes
The Pintech PT-5260 is a differential probe that converts floating or high-voltage signals to a ground-referenced output for oscilloscopes and data-acquisition equipment. It provides selectable 500X and 5000X attenuation with a typical accuracy of ±2%. The probe connects via a standard BNC cable and operates from a 9V DC adapter.
Engineers measuring motor drives
Suited for engineers who need to capture differential signals up to 60kV peak-to-peak at bandwidths of 60MHz (500X) or 20MHz (5000X). Not suited for users who require higher bandwidth than 60MHz or who need a probe powered directly from the oscilloscope without an external adapter.
60kV peak-to-peak maximum differential input
The single specification that decides fit is the 60kVp-p maximum differential test voltage at the 5000X setting, with a 6kVp-p limit at 500X. Exceeding these voltages risks damage and invalidates the ±2% accuracy figure.
Highlights
- Safely measure up to 60 kV peak-to-peak differential signals
- DC to 60 MHz bandwidth at 500× attenuation for fast edges
- ±2 % typical accuracy ensures reliable high-voltage readings
- 500× and 5000× attenuation ratios cover a wide voltage range
- BNC output works with any oscilloscope input
Specifications
| Selling Unit | Each |
|---|---|
| Type | Oscilloscopes Probe |
| Brand | PINTECH |
| Model | PT-5260 |
| Size/Dimensions | 275*147*34mm |
| Includes | Probe Hook x 2, Alligator Clip x 2, BNC cable x 1, Grounding Cabe x 1 |
Questions about this item
What accessories come in the box and is a BNC cable included?
The kit includes the PT-5260 differential probe, an adapter, two probe hooks, two alligator clips, a BNC cable, a grounding cable, a high-voltage extension cord, an input cable and a manual.
When should I use the 500X setting versus the 5000X setting?
Use 500X for signals up to 6 kVp-p or 3 kV DC with 60 MHz bandwidth; switch to 5000X for up to 60 kVp-p or 30 kV DC where bandwidth is 20 MHz.
What does the 60 MHz bandwidth mean when the probe is connected to my oscilloscope?
At 500X attenuation the probe passes signals from DC to 60 MHz with a 5.8 ns rise time; at 5000X the usable bandwidth drops to 20 MHz and rise time increases to 17.8 ns.