We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Pintech

Pintech N2008Apro differential probe 200MHz 1kV 1000X/100X measurement tool

SKU CH-VSWQ-09X4S MPN N2008Apro

A 200 MHz differential probe with 1000X and 100X attenuation for 1 kV measurements

  • Size/Dimensions187*83*41mm
  • Selling UnitEach
  • TypeElectrical Testing & Measuring
  • Accuracy±1%
  • Standards/CertificationsCE
  • 200 MHz bandwidth captures fast signal transitions
  • 1 kV peak-to-peak rating handles high-voltage motor circuits
  • Switchable 100X and 1000X attenuation adapts to signal level
  • 75 ns rise time resolves rapid edges with ±1 % accuracy
  • BNC output and 5 MHz limit filter simplify oscilloscope connection

Differential Probe for Oscilloscopes

The Pintech N2008Apro is a high-voltage differential probe designed for engineers and technicians who need to convert floating two-point signals into ground-referenced measurements for oscilloscopes, meters, or data acquisition systems. It is suited for testing motor circuits and other power electronics where ground isolation is required. It is not intended for users who need more than two selectable attenuation ratios or bandwidth beyond 200MHz.

BNC Interface and Bandwidth Limits

The probe connects via a standard BNC output with a 90 cm cable, making it compatible with any oscilloscope presenting a 1M input impedance. Bandwidth changes with the attenuation setting: at 100X the range is DC to 70MHz, while at 1000X it extends to DC-200MHz. A selectable 5MHz bandwidth limit filter is built in to reduce high-frequency noise when full bandwidth is not required.

Attenuation Ratio Determines Voltage Range

The single specification that decides suitability is the dual attenuation rate of 1000X and 100X, which sets the maximum measurable voltage. At 1000X the probe handles up to 1kV peak-to-peak differential or 500V DC, while at 100X the limits are 100V peak-to-peak and 50V DC. Common-mode RMS voltage is rated at 350V for both settings.

Highlights

  • 200 MHz bandwidth captures fast signal transitions
  • 1 kV peak-to-peak rating handles high-voltage motor circuits
  • Switchable 100X and 1000X attenuation adapts to signal level
  • 75 ns rise time resolves rapid edges with ±1 % accuracy
  • BNC output and 5 MHz limit filter simplify oscilloscope connection

Specifications

BrandPINTECH
ModelN2008Apro
Size/Dimensions187*83*41mm
Selling UnitEach
TypeElectrical Testing & Measuring
Accuracy±1%
Standards/CertificationsCE

Questions about this item

Which attenuation setting should I choose, 100X or 1000X?

Use 100X for signals up to 100 V peak-to-peak or 50 V DC, giving 70 MHz bandwidth. Switch to 1000X for signals up to 1 kV peak-to-peak or 500 V DC, giving 200 MHz bandwidth.

What does the 200 MHz bandwidth mean when I am measuring a fast edge?

At the 1000X setting the probe reaches 200 MHz, so a 1.75 ns rise time is captured accurately. At 100X the bandwidth drops to 70 MHz, so the same edge would appear slower on screen.

How does the BNC interface limit what I can connect?

The 90 cm BNC cable plugs directly into any oscilloscope with a 1 MΩ input, so the probe works with every standard bench scope without extra adapters.