Parker
Parker LLD 082S HVAC Control 1 1/2 ton 1/4 in
Liquid-line filter dryer, 082S model with 1/4 in solder connections and 75/25 desiccant blend for all CFC, HCFC and HFC refrigerants
- Filters moisture and acid with 75/25 desiccant blend
- Handles R-22 and R-410A systems up to 1 1/2 ton capacity
- Solder connection fits 1/4 in line for secure installation
- Steel shell resists corrosion in demanding HVAC environments
- Compact 5 5/8 in overall length saves space in tight runs
Parker LLD 082S Filter Dryer
The Parker LLD 082S is a liquid line filter dryer built for HVAC and refrigeration systems. It uses a 75/25 desiccant blend to remove moisture and debris from the refrigerant circuit. The steel body handles all common CFC, HCFC and HFC refrigerants including R-22 and R-410A at 1 1/2 ton capacity.
Suits solder connections only
Installers who need a 1/4 inch solder connection and 1 1/2 ton rating will find this part fits directly. Technicians requiring flare fittings, larger connection sizes or higher tonnage ratings should select a different model. The fixed cut-out length of 4 11/16 inches also limits use in tight spaces.
1/4 inch solder connection
The single specification that decides fit is the 1/4 inch solder connection type. This determines whether the dryer can be brazed into the existing liquid line without adapters. Verify the tube diameter and joining method before ordering.
Highlights
- Filters moisture and acid with 75/25 desiccant blend
- Handles R-22 and R-410A systems up to 1 1/2 ton capacity
- Solder connection fits 1/4 in line for secure installation
- Steel shell resists corrosion in demanding HVAC environments
- Compact 5 5/8 in overall length saves space in tight runs
Specifications
| Brand | PARKER |
|---|
Questions about this item
What size copper tubing do I need to solder this filter/dryer into my liquid line?
The connection size is 1/4 in, so you need 1/4 in copper tubing and a suitable solder joint.
Will the 75/25 desiccant blend handle the R-410A charge in my existing 1 1/2 ton system?
Yes, the filter/dryer is rated for 1 1/2 ton R-410A capacity and works with all CFC, HCFC and HFC refrigerants.
How can I confirm the filter/dryer is flowing properly after I solder it in?
Check for a normal liquid-line temperature drop across the 5 5/8 in body and verify sight-glass clarity downstream.