Owens Corning
Owens Corning 147377 Drain Trap Tan 3-1/8 in 2 in Wall 3 ft
Fiberglass pipe insulation with ASJ facing fits 3-1/8 in copper tube and withstands 0 to 1,000 °F
- TypeDrain Components
- MaterialHAWA
- ColorTan
- High R-value 14.6 cuts heat loss on hot pipes
- ASJ facing meets flame spread 25 and smoke developed 50 ratings
- Slit tube with adhesive flap speeds installation on 3-1/8 in copper
- Fiberglass insulation withstands 0 to 1000 °F operating range
- Plenum rated for use in air-handling spaces
Insulation for 3 1/8 in copper tube
This fiberglass tube insulation fits copper tubing with a 3 1/8 inch outside diameter. It provides thermal protection across a temperature range of 0 to 1,000 degrees Fahrenheit. The product is plenum rated with a flame spread index of 25 and smoke developed index of 50. An ASJ facing and slit design with adhesive flap simplify installation.
Suited for high-temperature pipe runs
Mechanical contractors insulating hot-water or steam lines in commercial buildings will value the high temperature rating and plenum compliance. Installers needing a flexible foam product or a lower R-value for chilled water should consider other materials. The rigid fiberglass form and 2 inch wall make it unsuitable for tight retrofit spaces where thinner wrap is required.
R-value 14.6 at 2 inch wall thickness
The insulation delivers an R-value of 14.6 through its 2 inch thick fiberglass wall. This single thermal resistance figure determines whether the product meets the energy code or system design specification for the intended piping application.
Highlights
- High R-value 14.6 cuts heat loss on hot pipes
- ASJ facing meets flame spread 25 and smoke developed 50 ratings
- Slit tube with adhesive flap speeds installation on 3-1/8 in copper
- Fiberglass insulation withstands 0 to 1000 °F operating range
- Plenum rated for use in air-handling spaces
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Color | Tan |
| Brand | Owens Corning |
| Model | 147377 |
Questions about this item
What does an R-value of 14.6 mean once the insulation is installed on a 3-1/8 in copper tube?
It provides thermal resistance of 14.6, reducing heat loss or gain on the pipe across the 2 in wall thickness.
How does the ASJ facing with a flame spread index of 25 and smoke developed index of 50 affect where this can be used?
The facing meets plenum-rated requirements, allowing installation in air-handling spaces per building codes.
What clearance is needed to fit the 2 in wall thickness around a 3-1/8 in copper tube?
The tube slips over the pipe, adding 2 in of insulation on each side for a total outside diameter of about 7-1/8 in.