We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Nippon Labs

Nippon Labs 30POW-10W1-L62013-10 computer power cord NEMA L6-20P to IEC-60320-C13 14 AWG 10 ft

SKU CH-J5Y0-RN356 MPN 30POW-10W1-L62013-10

A 10 ft locking power cord with 14 AWG conductors rated 20 A at 250 V for secure data-centre connections

  • TypePower
  • ColorBlack
  • Length10 ft.
  • Connector Number2
  • Connector DetailNEMA L6-20P to IEC-60320-C13
  • SpecificationsConnector A: NEMA L6-20P Locking Connector B: IEC-60320-C13
  • Locking NEMA L6-20P secures critical equipment connections
  • 14 AWG conductors handle 20 A at 250 V
  • Ten-foot length reaches rack PDUs in data centres
  • Fully moulded SJT jacket resists wear in wiring closets
  • UL and cUL listed plus RoHS and REACH compliant

Target Application

This power cord connects servers and network equipment that require a high-current 250 V supply to a NEMA L6-20R outlet in a data centre or wiring closet. The locking plug prevents accidental disconnection of critical infrastructure. It is not for standard desktop PCs or consumer peripherals that use NEMA 5-15R or C14 inlets.

Decisive Specification

The cable carries a 20 A / 250 V rating on 14 AWG SJT conductors with a NEMA L6-20P locking plug and an IEC-60320-C13 connector. This combination determines whether the cord matches the inlet and circuit capacity of the target device. Equipment needing a different voltage, amperage or connector type cannot use this lead.

Build Integration

The ten-foot length provides routing flexibility between rack-mounted gear and overhead or floor-mounted power distribution units. The fully moulded, UL and cUL listed construction meets data-centre safety standards while RoHS and REACH compliance satisfies environmental requirements. The cord occupies a single L6-20R receptacle and frees the installer from sourcing separate high-gauge jumpers.

Highlights

  • Locking NEMA L6-20P secures critical equipment connections
  • 14 AWG conductors handle 20 A at 250 V
  • Ten-foot length reaches rack PDUs in data centres
  • Fully moulded SJT jacket resists wear in wiring closets
  • UL and cUL listed plus RoHS and REACH compliant

Specifications

BrandNippon Labs
Model30POW-10W1-L62013-10
TypePower
ColorBlack
Length10 ft.
Connector Number2
Connector DetailNEMA L6-20P to IEC-60320-C13
SpecificationsConnector A: NEMA L6-20P Locking
Connector B: IEC-60320-C13
Conductor: SJT 14 AWG. x 3C
Amp/Voltage Rating: 20A/250V
Wire Gauge14 AWG
ConductorSJT 14 AWG. x 3C
FeaturesHigh voltage NEMA L6-20P to C13 power cord is designed for connecting network devices that require higher-rated or heavier-gauge cabling to L6-20R wall outlet in a data center or network wiring closet.
The NEMA L6-20P locking connector allows it to be securely plugged into the power outlet for important equipment.
This heavy duty 14 AWG power cord is fully molded for durability.
UL and cUL listed.
All relevant materials are complied with RoHS and REACH directive.
Shipping weight0.36 kg
Package size191 × 76 × 51 mm

Questions about this item

How does the 20 A / 250 V rating translate when the cord is plugged into a rack-mounted server?

The 14 AWG SJT conductors and NEMA L6-20P locking plug deliver a full 20 A at 250 V to the IEC C13 inlet, so a server drawing up to 5 kW runs without voltage drop or connector heating.

What does the NEMA L6-20P locking interface actually secure against in a data-centre rack?

The twist-lock blades mate with an L6-20R receptacle and resist accidental pull-out from cable vibration or tray movement, keeping critical gear powered during maintenance.

What clearance and mounting depth does the 10 ft cord need behind a 42 U cabinet?

At 10 ft the cord reaches floor-mounted PDUs from mid-rack, and the fully moulded C13 and L6-20P ends fit standard IEC inlets and locking receptacles without adapters.