Nippon Labs
Nippon Labs 30POW-10W1-C1514-15 computer power cord C15 to C14 14 AWG 15 ft black
Heavy-duty 14 AWG cord connects high-temperature gear to a C14 inlet on a PDU or UPS, with a C15 plug that also fits C16 sockets
- TypePower Cord
- ColorBlack
- Length15 ft.
- Connector Number2
- Connector DetailIEC-60320-C15 to IEC-60320-C14
- SpecificationsConnector A: IEC-60320-C15 Connector B: IEC-60320-C14 Conduc
- Connect high-temperature gear to C14 PDU or UPS in data centres
- C15 connector fits both C16 and C14 inlets for flexible mounting
- Heavy-duty 14 AWG SJT conductors deliver reliable 15 A power
- Fully moulded strain relief protects connections during rack moves
- UL and cUL listed with RoHS and REACH compliant materials
Connectors and Length
This power cord provides a 15 ft link between equipment using a C15 connector and a power source with a C14 inlet. The 14 AWG conductors are rated for 15 A and built to UL SJT specifications. The fully moulded design adds mechanical durability for rack installations.
Compliance and Build
UL and cUL listings confirm the cable meets recognised safety standards for North American use. All materials comply with RoHS and REACH directives, restricting hazardous substances in the assembly. The heavy duty construction is intended for continuous operation in data centre environments.
High Temperature Rack Use
The C15 plug fits both C16 and C14 inlets, making it suitable for network hardware or other high temperature devices connected to a PDU or UPS. Buyers who need a different connector pairing or a shorter cable for desktop use should look at something else.
Highlights
- Connect high-temperature gear to C14 PDU or UPS in data centres
- C15 connector fits both C16 and C14 inlets for flexible mounting
- Heavy-duty 14 AWG SJT conductors deliver reliable 15 A power
- Fully moulded strain relief protects connections during rack moves
- UL and cUL listed with RoHS and REACH compliant materials
Specifications
| Brand | Nippon Labs |
|---|---|
| Model | 30POW-10W1-C1514-15 |
| Type | Power Cord |
| Color | Black |
| Length | 15 ft. |
| Connector Number | 2 |
| Connector Detail | IEC-60320-C15 to IEC-60320-C14 |
| Specifications | Connector A: IEC-60320-C15 Connector B: IEC-60320-C14 Conductor: UL SJT 14 AWG. x 3C |
| Wire Gauge | 14 AWG |
| Conductor | UL SJT 14 AWG. x 3C |
| Features | Connect network hardware or other high-temperature equipment to a PDU or UPS with C14 type input in a data center. IEC320 C15 connector can fit into both C16 and C14 inlets. This heavy duty 14 AWG power cord is fully molded for durability. UL and cUL listed. All relevant materials are complied with RoHS and REACH directive. |
| Shipping weight | 0.59 kg |
| Package size | 203 × 76 × 51 mm |
Questions about this item
Will the C15 connector or the 14 AWG conductors need replacement after extended use in a high-temperature rack?
The cord is fully moulded and uses UL SJT 14 AWG conductors rated for 15 A, so no user-serviceable parts are expected to wear out under normal data-centre conditions.
What electrical or thermal limit is reached first when the cord runs continuously at its 15 A rating?
The 14 AWG SJT conductors set the continuous-current ceiling at 15 A; the C15 connector is rated for higher inlet temperatures, so the conductor ampacity is the governing limit.
Does the cable become audibly noisy or excessively warm when powering a PDU all day?
A passive 15 ft 14 AWG SJT cord produces no audible noise and runs only slightly above ambient temperature when carrying its rated 15 A load.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.