Mueller Industries, Inc.
Mueller Industries, Inc. 620F 7/8 in OD 60 ft L trap
Copper coil tubing for potable water, 60 ft length with 7/8 in outside diameter and 0.045 in wall thickness
- TypeDrain Components
- 60 ft coil reduces joints for faster installs
- Type L copper wall rated 466 psi at 200 °F
- Meets ASTM B88, NSF 372 and NSF 61 for potable water
- Seamless C12200 copper resists corrosion and scaling
- Soft temper allows hand bending without special tools
Copper L-Type Coil Tubing
This 60 ft coil of seamless copper tubing is made to ASTM B88 Type L dimensions for potable-water distribution. The soft temper allows hand bending without special tools, suiting residential and light-commercial plumbing installs.
7/8 in Outside Diameter
The tube measures 7/8 in OD with a 0.045 in wall, yielding a 0.785 in inside diameter and a 466 psi rating at 200 °F. That single pressure-class figure decides whether the coil meets the design pressure of the system you are piping.
Soft Temper Coil for Tight Runs
Supplied as a 60 ft coil, the tubing feeds through joists and around obstacles without joints, reducing leak paths and fitting count. It is certified to NSF/ANSI/CAN 61 and NSF 372 for drinking-water contact, and the C12200 alloy withstands continuous exposure up to 400 °F.
Highlights
- 60 ft coil reduces joints for faster installs
- Type L copper wall rated 466 psi at 200 °F
- Meets ASTM B88, NSF 372 and NSF 61 for potable water
- Seamless C12200 copper resists corrosion and scaling
- Soft temper allows hand bending without special tools
Specifications
| Type | Drain Components |
|---|---|
| Brand | Mueller Industries |
| Model | 620F |
Questions about this item
What does the 466 psi pressure rating mean when the tubing is installed in a hot water system?
The 466 psi rating applies at 200 degrees F; at the maximum operating temperature of 400 degrees F the allowable pressure will be lower, so design the system for the actual service temperature.
What do the NSF 372 and NSF/ANSI/CAN 61 standards guarantee for this copper coil?
NSF 372 certifies lead-free material for potable water, and NSF/ANSI/CAN 61 confirms the tubing meets health-effects requirements for drinking-water contact.
How much clearance is needed to uncoil and route the 60-foot length of 7/8-inch OD tubing?
The soft-temper coil ships in a 60-foot continuous length with a 7/8-inch outside diameter and 0.045-inch wall, so allow enough straight run and bend radius for the full coil to be laid out without kinking.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor 70204 Acrylic Coated Polyester Gray Hot Shot BoatGuard Boat Cover
- Transparent
BoatBuckle F12071 Kwik-Lok Gunwale Tie-Down Stainless Steel
- Transparent