Mueller Industries, Inc.
Mueller Industries, Inc. 1WJP3 1-1/2" Hub PVC DWV Sanitary Tee trap
A Schedule 40 PVC sanitary tee with a 1-1/2 inch hub connection for DWV systems, rated to 140°F and meeting ASTM D1784 cell class 12454
- TypeDrain Components
- ColorWhite
- Schedule 40 PVC rated for 140 °F service
- Hub connection fits 1-1/2 in DWV pipe runs
- ASTM D1784 cell class 12454 material spec
- White finish matches standard plumbing aesthetics
- Sanitary tee directs flow in drain systems
1-1/2" PVC Sanitary Tee Hub
This Mueller Industries 1WJP3 fitting connects 1-1/2 inch pipes in a drain, waste and vent system using a hub connection. It is made from Schedule 40 PVC with a white finish and meets ASTM D1784 cell class 12454 standards. The part is supplied new and is not rated for pressure applications.
DWV System Compatibility
The sanitary tee design directs flow between horizontal and vertical branches without creating turbulence that can trap debris. Its hub connection accepts solvent-weld pipe for a permanent, leak-free joint in gravity-fed drainage. The maximum operating temperature is 140 degrees Fahrenheit.
Non-Pressure Application Constraint
This fitting is explicitly not rated for pressure applications, so it cannot be used in supply lines, compressed air systems or any pressurised circuit. Installers needing a pressure-rated tee must select a different product class.
Highlights
- Schedule 40 PVC rated for 140 °F service
- Hub connection fits 1-1/2 in DWV pipe runs
- ASTM D1784 cell class 12454 material spec
- White finish matches standard plumbing aesthetics
- Sanitary tee directs flow in drain systems
Specifications
| Type | Drain Components |
|---|---|
| Color | White |
| Brand | Mueller Industries |
| Model | 1WJP3 |
Questions about this item
Will the Schedule 40 PVC hub connections need re-gluing or seal replacement over time?
Solvent-welded Schedule 40 hub joints are permanent when installed correctly; no scheduled re-gluing or seal replacement is required.
What temperature limit governs continuous drain flow through this sanitary tee?
The PVC material is rated for a maximum continuous temperature of 140 degrees F.
Does the fitting generate noise or heat when waste water runs through it all day?
As a passive PVC fitting it produces no heat and adds no mechanical noise beyond normal water flow sound.