Mueller Industries, Inc.
Mueller Industries, Inc. 05841 4 in PVC DWV Double Wye trap
4-inch PVC DWV double wye with four socket hubs for gravity-flow drainage systems
- TypeDrain Components
- ColorWhite
- 4-inch hub connects four pipes in one fitting
- Schedule 40 PVC handles gravity-flow drainage reliably
- White finish matches standard DWV installations
- Rated for -20 to 140 degrees F operating range
- 8-1/4 inch overall length fits compact drain layouts
4 in PVC DWV Double Wye
The Mueller Industries 05841 is a Schedule 40 PVC double wye fitting designed for drain waste and vent systems. It connects four 4 in hub sockets with solvent weld joints for gravity flow plumbing installations. The white fitting handles waste lines in residential and commercial projects.
Thermals noise and power draw
PVC construction resists corrosion and chemical attack from -20 to 140 degrees Fahrenheit without mechanical parts that generate noise or consume power. The Schedule 40 wall thickness handles gravity flow pressure at ambient temperature. No electrical supply or cooling is required.
Build fit and clearance
Each of the four hubs accepts 4 1/2 in outside diameter pipe with a 5 in socket depth for solvent cement joining. The 8 1/4 in overall length determines the space needed in the pipe run. No seals are included so primer and cement must be supplied separately.
Highlights
- 4-inch hub connects four pipes in one fitting
- Schedule 40 PVC handles gravity-flow drainage reliably
- White finish matches standard DWV installations
- Rated for -20 to 140 degrees F operating range
- 8-1/4 inch overall length fits compact drain layouts
Specifications
| Type | Drain Components |
|---|---|
| Color | White |
| Brand | Mueller Industries |
| Model | 05841 |
Questions about this item
How do I install the Mueller 05841 double wye and what step is often missed?
Clean each hub and pipe end, apply primer then PVC cement, insert fully and hold; the step most often missed is priming both surfaces before cementing.
What maintenance will the Mueller 05841 double wye need later?
No routine maintenance is required; if a joint leaks later, the affected section must be cut out and re-glued because solvent-welded PVC cannot be tightened.
What is the first limit that appears under sustained use of the Mueller 05841 double wye?
The maximum operating temperature is 140 degrees F, so sustained hot-water flow above that limit will degrade the PVC before any pressure issue arises.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor 70204 Acrylic Coated Polyester Gray Hot Shot BoatGuard Boat Cover
- Transparent
BoatBuckle F12071 Kwik-Lok Gunwale Tie-Down Stainless Steel
- Transparent