Monoprice Inc.
Monoprice Inc. 140060 computer power cord 6ft IEC 60320 C20 to C13 14AWG 15A black
Six-foot black extension cord with IEC 60320 C20 plug to C13 receptacle, 14AWG rated 15A for rack equipment and PDU connections
- TypeOthers
- ColorBlack
- Connector Number2
- 6 ft length extends reach to distant outlets
- IEC 60320 C20 plug connects to high-output equipment
- IEC 60320 C13 receptacle fits standard device inlets
- 14AWG conductors rated for 15 A current
- Black jacket allows quick identification in dense racks
Six-foot C20-to-C13 extension cord
This six-foot black cord carries a C20 plug on one end and a C13 receptacle on the other, letting you extend the AC supply to rack-mounted gear or desktop peripherals. The 14 AWG conductors are rated for 15 A, matching the C20 connector specification. It is built for indoor use in data cabinets or workstation clusters.
Suits high-current rack gear.
Installations that terminate in IEC 60320 C20 outlets and need a C13 inlet will find the rating and pin layout correct. Builders whose equipment uses the more common C14 inlet cannot plug this cord directly and would need a different cable assembly. The 15 A capacity also exceeds what a C13-only circuit typically provides, so it is not a drop-in replacement for lighter-duty cords.
Connector pair decides fit
The defining detail is the IEC 60320 C20 plug mated to an IEC 60320 C13 receptacle; only devices and power distribution units presenting that exact combination can use this cord without adapters.
Highlights
- 6 ft length extends reach to distant outlets
- IEC 60320 C20 plug connects to high-output equipment
- IEC 60320 C13 receptacle fits standard device inlets
- 14AWG conductors rated for 15 A current
- Black jacket allows quick identification in dense racks
Specifications
| Brand | Monoprice |
|---|---|
| Model | 140060 |
| Type | Others |
| Color | Black |
| Connector Number | 2 |
Questions about this item
Does the 14 AWG cable run hot when powering a 15 A load continuously?
The 14 AWG conductors are rated for 15 A, so the cord stays within its thermal limits during continuous full-load operation.
What equipment must already have a C20 inlet and a C13 outlet for this cord to connect?
You need a source with an IEC 60320 C20 plug — such as a high-output PDU or rack supply — and a device with a C13 inlet like a server or monitor.
Will this C20-to-C13 lead work with older rack gear that still uses C13 inlets?
Yes, the C13 receptacle mates with any legacy C14 inlet, so existing servers and peripherals connect without adapters.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.