MINUTEMAN
MINUTEMAN PRO750RT2U 750VA UPS 2U rack/tower
A 750 VA uninterruptible power supply with automatic voltage regulation, eight NEMA 5-15R outlets and a 2U rack or tower form factor
- Parts3 Year
- 750 VA capacity keeps critical gear running
- Automatic voltage regulation corrects 103-136 V input without battery drain
- 2U rack or tower form factor fits standard enclosures
- 10 ms transfer time protects sensitive electronics during outages
- Energy Star certified with cTUVus safety approval
750VA Rack/Tower UPS
The MINUTEMAN PRO750RT2U is a 750VA uninterruptible power supply with automatic voltage regulation. It fits a 2U rack space or stands as a tower. The unit protects connected equipment from power disturbances. It is suited for network closets, small servers and workstations needing battery backup.
Input Range and Transfer Time
The UPS accepts an input voltage window of 103 to 136 V AC and delivers 120 V AC output. When utility power falls outside this range, the unit switches to battery in 10 ms. At full load of 525 W, the internal battery provides approximately five minutes of runtime for safe shutdown.
Installation Checks
Verify that your equipment uses NEMA 5-15P plugs to match the eight NEMA 5-15R receptacles. Confirm the rack or shelf can accommodate the 3.4 inch height, 18.9 inch width and 16.1 inch depth. The unit weighs 31.30 lb, so ensure mounting hardware and support are rated for this weight.
Highlights
- 750 VA capacity keeps critical gear running
- Automatic voltage regulation corrects 103-136 V input without battery drain
- 2U rack or tower form factor fits standard enclosures
- 10 ms transfer time protects sensitive electronics during outages
- Energy Star certified with cTUVus safety approval
Specifications
| Brand | MINUTEMAN POWER |
|---|---|
| Parts | 3 Year |
| Shipping weight | 17.24 kg |
| Package size | 584 × 559 × 254 mm |
Questions about this item
Should I choose the 750 VA or 525 W rating for my load calculation?
Size the load by the 525 W figure because that is the real power the UPS can deliver; the 750 VA rating is the apparent power limit.
What does the 5 minute runtime at full load mean for my equipment?
With a full 525 W load the battery will last about 5 minutes, giving time to save work and shut down safely.
How does the NEMA 5-15P input and 5-15R outlets affect what I can plug in?
The UPS plugs into a standard 120 V 15 A wall outlet and provides eight 5-15R receptacles for 120 V devices up to the 525 W total.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Crivon No Clean Rosin Flux Syringe + Solder Wick Braid Kit
- Out-Opening, Narrow…
- 1 Year
Zoro Select 60" x 28" Equipment Cover 1 mil Clear PK 150
- Packing Peanuts & F…
Zoro Select 9LAP2 Poly Tubing 22 in x 1075 ft 4 mil Clear
- Packing Peanuts & F…



