Milwaukee Valve
Milwaukee Valve UPBA-480B 200 psi 2 in manual brass ball valve
Full-port brass ball valve with locking lever handle rated for 200 psi water service
- TypeOther
- Full-port design enables unrestricted flow
- Chrome-plated brass ball resists corrosion
- Locking lever handle prevents accidental operation
- Brass two-piece body rated to 200 psi
- Vacuum service rated to 29.92 in Hg
Two-inch brass ball valve
The Milwaukee Valve UPBA-480B is a manual two-way ball valve built from brass with a chrome-plated brass ball. It uses a full-port design and a straight body style for water service. A locking lever handle allows secure shut-off in plumbing installations. The two-piece body construction simplifies maintenance when required.
Pressure and vacuum limits
Maximum operating pressure is rated at 200 psi for water media. Steam and combustible gas pressures are not rated for this model. Vacuum service is rated to 29.92 in Hg, covering full vacuum conditions. The valve does not carry a 3-A sanitary standard rating for food or dairy use.
Build and daily implications
Brass body and chrome-plated ball resist corrosion in typical water systems. The two-piece construction allows the valve to be serviced without removing the entire line. A locking lever handle prevents accidental operation in busy mechanical rooms. Press-end connections suit press-fit copper piping systems for flame-free installation.
Highlights
- Full-port design enables unrestricted flow
- Chrome-plated brass ball resists corrosion
- Locking lever handle prevents accidental operation
- Brass two-piece body rated to 200 psi
- Vacuum service rated to 29.92 in Hg
Specifications
| Brand | MILWAUKEE VALVE |
|---|---|
| Type | Other |
Questions about this item
Which connection style should I choose for the UPBA-480B 2 in brass ball valve?
The valve uses a press connection, so select the press version to match your press-fit copper piping system.
What does the 200 psi rating mean when the valve is installed in a water line?
It indicates the maximum operating pressure for water service; the valve will hold up to 200 psi under normal flow conditions.
How does the press interface affect the pressure limit in practice?
The press ends are rated to the same 200 psi operating pressure, so the joint does not reduce the valve's pressure capability.