Micro Connectors
Micro Connectors Hospital Grade Power Cord 10 ft 18AWG NEMA 5-15PHG to IEC-60320-C13 Black
Hospital-grade 18 AWG cord connects medical or IT equipment to a NEMA 5-15PHG outlet with a C13 plug, rated 10 A at 125 V
- Hospital-grade connectors ensure reliable grounding in medical environments
- 10 ft length provides flexible equipment placement options
- Heavy-duty 18 AWG conductors support 10A at 125V
- UL, cUL and CSA certifications confirm safety compliance
- Fully molded design delivers long-lasting durability for critical equipment
Hospital-Grade Power Cord
This 10 ft hospital-grade power cord connects medical devices, computers, or monitors to NEMA 5-15PHG outlets. It features fully molded NEMA 5-15PHG and IEC-60320-C13 connectors built to strict grounding and durability standards. The heavy-duty 18 AWG SJT construction suits mobile medical carts, servers, UPS units, and PDUs.
Replaces Standard Cords in Clinical Settings
The cord upgrades from ordinary office cables when regulatory compliance and mechanical security are required. Its UL, cUL, and CSA listings plus RoHS and REACH material compliance satisfy healthcare facility mandates. The jump is worth it wherever patient-vicinity equipment demands verified grounding reliability and assembly strength.
10 A at 125 V with 10 ft Reach
The 18 AWG three-conductor cable delivers a 10 A, 125 V rating adequate for most workstation, monitor, and small-server loads. The 10 ft length provides placement flexibility for carts or rack gear without excess slack. It runs out on high-draw appliances exceeding 10 A or installations needing longer runs than 10 ft.
Highlights
- Hospital-grade connectors ensure reliable grounding in medical environments
- 10 ft length provides flexible equipment placement options
- Heavy-duty 18 AWG conductors support 10A at 125V
- UL, cUL and CSA certifications confirm safety compliance
- Fully molded design delivers long-lasting durability for critical equipment
Specifications
No published specifications for this item yet.
Questions about this item
What plug and inlet does the 10 ft cord use?
It has a NEMA 5-15PHG hospital-grade plug on one end and an IEC-60320-C13 connector on the other.
How do I install the cord, and what step is often missed?
Push the C13 fully onto the device inlet until it clicks, then insert the NEMA 5-15PHG plug firmly into the hospital-grade outlet; the click is the step people skip.
When should the cord be replaced?
Replace it if the SJT 18 AWG jacket shows cuts, the moulded strain relief cracks, or the ground pin becomes loose, since the cord carries 10 A at 125 V.