MASTECH
MASTECH MS7221 Volt/mA Calibrator 0-10V 0-24mA
Sources and measures 0-10 V DC and 0-24 mA loops with 0.015 % accuracy and 1 µA resolution
- TypeDigital Multimeters
- Measures loop current to 0.015% accuracy with 1uA resolution
- Sources and simulates DC current up to 24 mA for loop testing
- Sources DC voltage to 100 mV or 10V with 0.02% precision
- Built-in 24V loop supply powers transmitters while measuring current
- High-count 88888 display shows fine detail for calibration work
Purpose and user
The MASTECH MS7221 is a portable calibrator for technicians who source and measure DC voltage up to 10 V and current loops up to 24 mA. It suits process-plant commissioning, PLC loop verification and transmitter bench checks where a single handheld tool must both simulate and read signals.
Capacity and headroom
The instrument sources or measures 0–100 mV and 0–10 V with ±0.02 % accuracy and handles 0–24 mA loops at ±0.015 % with 1 µA resolution. A built-in 24 V loop supply powers transmitters while current is measured, but the unit cannot source and measure at the same time.
Thermals, noise and power
Battery-powered from a 9 V 6F22 cell, the calibrator runs cool and silent during typical loop tests. The 88888-count display remains readable without backlight, and the compact 19 × 9.0 × 4.3 cm enclosure adds no fan noise or noticeable heat in normal use.
Highlights
- Measures loop current to 0.015% accuracy with 1uA resolution
- Sources and simulates DC current up to 24 mA for loop testing
- Sources DC voltage to 100 mV or 10V with 0.02% precision
- Built-in 24V loop supply powers transmitters while measuring current
- High-count 88888 display shows fine detail for calibration work
Specifications
| Type | Digital Multimeters |
|---|
Questions about this item
Can the MS7221 0-10 V source work with my existing 0-10 V PLC inputs?
The calibrator sources 0-100 mV and 0-10 V DC with ±0.02 % accuracy, matching standard 0-10 V process signal ranges used by many PLC analogue inputs.
How do I verify the MS7221 is measuring loop current correctly after connecting it?
The 88888-count display shows loop current with 1 µA resolution and ±0.015 % accuracy; compare the reading against a known reference transmitter to confirm operation.
What accessories come with the MS7221 and what must I supply myself?
The box includes the meter, two test leads, a carrying case and a user manual; you must provide a 9 V 6F22 (1604) battery for power.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lab Safety Supply Inc 667123 24 Well Tissue Culture Plate w/Lid PK50
- Assortments & Kits
Lab Safety Supply Inc 11L806 2mL Pipet Individually Wrapped PK600
- Assortments & Kits



