Madison
Madison Liquid Level Switch Poly Float
Vertical-mount liquid-level switch with a polypropylene float, SPST contact rated at .5 A and 240 V, 60 VA, 100 psi maximum pressure and 221 °F operating temperature
- TypeLight Switch
- Selectable switch function adapts to tank logic
- Polypropylene float and stem resist chemical corrosion
- Vertical open-tank mount fits 1/4 in NPT ports
- Rated for 100 psi and 221 °F operating limits
- SPST contacts handle .5 A at 240 V
Vertical Tank Level Switch
The Madison liquid level switch uses a polypropylene float and stem to detect fluid height in a vertically mounted tank. It threads into a 1/4 inch NPT opening and operates in temperatures up to 221 degrees Fahrenheit. The SPST contact form handles up to 0.5 amps at 240 volts with a 60 VA rating. This new switch suits industrial or automotive tanks requiring a compact, corrosion-resistant sensor.
Pressure and Electrical Limits
The polypropylene body withstands a maximum pressure of 100 psi, making it suitable for low-pressure vessels only. Electrical capacity is capped at 60 VA, 0.5 amps and 240 volts, so the switch must drive a relay or contactor rather than a heavy load directly. Exceeding the temperature or pressure ratings will damage the float assembly. Installers must verify that the tank pressure and control-circuit draw stay within these boundaries.
Selectable Switch Function
The single specification that decides fit is the selectable switch function, which lets the installer choose normally open or normally closed action on the same unit. This flexibility covers both fill-control and drain-control logic without stocking two different part numbers. If the application demands a fixed function or a different contact form such as SPDT, this model will not meet the requirement.
Highlights
- Selectable switch function adapts to tank logic
- Polypropylene float and stem resist chemical corrosion
- Vertical open-tank mount fits 1/4 in NPT ports
- Rated for 100 psi and 221 °F operating limits
- SPST contacts handle .5 A at 240 V
Specifications
| Brand | Madison |
|---|---|
| Type | Light Switch |
Questions about this item
Should I choose the vertical-mount version or a different mounting style?
This switch is built for vertical open-tank mounting with a 1/4 in NPT connection; no other mounting styles are offered.
What does the 60 VA rating mean when the switch is installed in my tank?
It allows up to 0.5 A at 240 V, so the circuit stays within 60 VA for reliable switching.
How does the 1/4 in NPT thread limit the tanks I can use?
The 1/4 in NPT tank connection fits only ports cut to that thread size and seals up to 100 psi.