Logico
Logico LSC4502-100 100ft 10 Gauge 2 Conductor Direct Burial Landscape Cable
100-foot 10-gauge two-conductor cable for direct-burial low-voltage landscape lighting up to 150 volts
- Length100 Feet
- Conductor Gauge10 Gauge
- Stranded 10 AWG copper carries current efficiently
- Direct burial PVC jacket resists moisture and UV
- Red polarity marker speeds correct connections
- 150 V rating suits low voltage outdoor circuits
- Heavy duty construction withstands cuts and abrasion
100 ft 10 AWG landscape cable
This 100-foot cable uses stranded bare copper conductors at 10 AWG with two conductors inside a heavy-duty PVC jacket. It is rated for direct burial and carries a 150-volt rating for low-voltage outdoor lighting circuits. The red polarity marker simplifies installation.
Suited for direct-burial lighting runs
Installers running low-voltage landscape lighting underground will find the UV-rated, waterproof jacket and industrial-grade ULECC construction appropriate. Projects that require a higher voltage rating, more than two conductors, or a different gauge should consider other options.
Sustained outdoor burial performance
The PVC jacket resists cuts, scrapes and tearing while protecting the conductors from moisture and UV exposure over long periods. Stranded copper maintains flexibility during pulling and settles reliably in trench environments without degradation.
Highlights
- Stranded 10 AWG copper carries current efficiently
- Direct burial PVC jacket resists moisture and UV
- Red polarity marker speeds correct connections
- 150 V rating suits low voltage outdoor circuits
- Heavy duty construction withstands cuts and abrasion
Specifications
| Length | 100 Feet |
|---|---|
| Conductor Gauge | 10 Gauge |
Questions about this item
What low-voltage transformer and connectors do I need to run this 10 AWG 2-conductor cable?
Use a transformer rated for 150 V or less and connectors that accept 10 AWG stranded copper; the red polarity marker helps you keep wiring consistent across the run.
Can I splice this 10 AWG direct-burial cable to an existing lower-gauge landscape run?
Yes, but the splice must be rated for direct burial and the circuit voltage must stay within the 150 V rating of this cable.
How do I verify the cable is performing correctly after burial?
Measure voltage at each fixture with a multimeter; readings should match the transformer output and show no unexpected drop along the 100 ft run.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Eclipse Tools 701-049 Uninsulated Wire Ferrule 18 AWG 1000 Pack
- Wire Connectors & T…
MIDWEST FASTENER CORP 76181 #1 Ceramic Twist-on Wire Connector 10PK
- Wire Connectors & T…
MIDWEST FASTENER CORP 76183 #7 Ceramic Twist-on Wire Connector 8PK
- Wire Connectors & T…