Logico
Logico KJ6226-100 Cat6 Keystone Jack 45 Degree Red 110 8P8C RJ45 100 Pack
A 100-pack of Cat6 keystone jacks with 45-degree 110 punch-down termination, dual 568A/568B color coding, and red finish for standard keystone wallplates
- ColorRed
- Easy termination with 110-punchdown tooling
- Supports both 568A and 568B wiring schemes
- Fits all standard keystone wallplates and patch panels
- 45-degree angled design eases cable routing
- 100 red jacks supplied for large-scale Cat6 installs
100-pack Cat6 keystone jacks
This bulk pack supplies one hundred red Cat6 keystone jacks for structured cabling projects. Each module uses a 110-style punch-down termination for quick wire seating. The 45-degree angled entry reduces cable strain in tight wallplates or patch panels. Installers running large drops will appreciate the consistent colour coding across every unit.
Thermals noise and power draw
Passive copper contacts generate no heat and draw no power during operation. The punch-down design requires no active components, so there is no fan noise or electrical consumption to consider. Performance stays stable across the full length of a Cat6 link without thermal throttling. The only energy used is the signal carried by the connected cables.
Dual 568A and 568B label sheets
Each jack includes dual-colour labels marked for both 568A and 568B (258A) wiring schemes. This removes the need to memorise pinouts or carry separate reference cards on site. The clear legend speeds up termination and reduces wiring errors in high-volume installs. No extra software or configuration tools are required to use the labelling system.
Highlights
- Easy termination with 110-punchdown tooling
- Supports both 568A and 568B wiring schemes
- Fits all standard keystone wallplates and patch panels
- 45-degree angled design eases cable routing
- 100 red jacks supplied for large-scale Cat6 installs
Specifications
| Brand | LOGICO |
|---|---|
| Model | KJ6226-100 |
| Color | Red |
Questions about this item
How do I punch down the 110 terminals on this 45-degree Cat6 keystone jack?
Strip the cable, seat each wire in the dual 568A/258B color slots, then press with a 110 punch-down tool until the blade cuts the insulation and locks the conductor.
What maintenance or replacement will the 100-pack of red Cat6 keystones need later?
The IDC contacts are rated for a single termination; if a link fails you must re-punch a fresh jack rather than reuse the same slots.
What limit appears first when these 45-degree jacks run sustained PoE+ loads?
The 45-degree cable exit can crowd adjacent ports in dense panels, so airflow and bend-radius clearance become the practical bottleneck before the Cat6 rating does.