A 100 A, 600 V Class J time-delay fuse with bolt mounting and a 200000 A interrupting rating
- 100 A rating supports heavy generator loads
- 600 VAC rating fits standard industrial circuits
- 200000 A interrupting rating clears massive faults
- Time-delay dual element tolerates motor inrush
- Bolt-mount terminals secure high-current connections
Industrial circuit protection
The Littelfuse JTD 100 is a Class J time-delay fuse rated at 100 A and 600 VAC for industrial power distribution panels, motor control centres and heavy-duty equipment circuits. It suits maintenance engineers and electricians who need reliable overcurrent protection with high interrupting capacity in bolt-mounted holders.
Critical ampere rating
The single specification that determines fit is the 100 A current rating; the fuse must match the circuit’s design current exactly, otherwise nuisance blowing or inadequate protection will occur. Buyers who need a different ampere value must select another rating from the same series.
Thermal behaviour and power dissipation
In normal operation the dual-element construction absorbs temporary overloads without opening, limiting temperature rise across the stone-sand and granular-quartz filler. The 200000 A interrupting rating ensures safe fault clearing with minimal energy let-through, keeping downstream components cool and reducing acoustic noise from violent interruption.
Highlights
- 100 A rating supports heavy generator loads
- 600 VAC rating fits standard industrial circuits
- 200000 A interrupting rating clears massive faults
- Time-delay dual element tolerates motor inrush
- Bolt-mount terminals secure high-current connections
Specifications
| Brand | Littelfuse |
|---|
Questions about this item
How does the 100 A rating work once the fuse is installed in a live circuit?
The 100 A rating means the fuse will carry that current continuously, while the time-delay dual-element design lets it ride through normal motor-start surges without opening.
What does the Class J 600 V rating limit in practice?
Class J at 600 VAC caps the maximum circuit voltage and guarantees the 200000 A interrupting rating will clear faults within that voltage range.
What does the bolt-mount terminal need to fit and secure the fuse?
Bolt-mount terminals require a matching bolted fuse block or panel with the correct spacing for the 1 1/16 inch diameter by 2 3/8 inch length body.