Bussmann
Bussmann T60030-2CR fuse block 30A 2 pole 600V
Two-pole fuse block rated 30 A and 600 V, accepts Class T fuses up to 1 1/2 in long, wire range 14 to 2 AWG, bolt-down mounting, CSA certified and UL listed
- Rated for 600 V AC/DC continuous operation
- Two-pole Class T block handles 30 A loads
- Accepts 14 to 2 AWG conductors securely
- CSA certified and UL listed for compliance
- Bolt-down fiberglass body resists vibration and heat
Industrial fuse block for Class T circuits
The Bussmann T60030-2CR is a two-pole fuse block rated for 30 A at 600 V AC/DC. It accepts Class T fuses up to 30 A and is built for industrial control panels and power-distribution equipment. The open, non-indicating design uses a fiberglass-reinforced thermoplastic body with bolt-down mounting. It is UL Listed and CSA Certified for compliant installations.
Capacity and headroom for 30 A loads
The block handles continuous loads up to 30 A with 600 V insulation, using box-lug connectors that accept 14 to 2 AWG wire. It fits Class T fuses measuring 1 1/2 in long by 9/16 in diameter and works with compatible series such as A6T, JJS, JLLS, LPT and Series T. The non-rejection style does not prevent insertion of incorrect fuse types, so correct fuse selection remains the installer's responsibility.
Integration into panels and enclosures
Bolt-down mounting secures the block to a panel or chassis without DIN rail hardware. Overall dimensions are 3.19 in length, 2.59 in width and 1.44 in height, leaving a compact footprint for tight cabinets. The open design allows visual inspection of fuse status but provides no built-in indication or rejection feature. Builders needing blown-fuse indication or keyed rejection should select a different block style.
Highlights
- Rated for 600 V AC/DC continuous operation
- Two-pole Class T block handles 30 A loads
- Accepts 14 to 2 AWG conductors securely
- CSA certified and UL listed for compliance
- Bolt-down fiberglass body resists vibration and heat
Specifications
| Brand | BUSSMANN |
|---|
Questions about this item
Will the 14 to 2 AWG box lugs on the T60030-2CR accept the existing conductors from my older panel?
The block uses box lug connectors rated for 14 to 2 AWG copper wire, so any solid or stranded conductor within that range can be secured directly under the lugs.
How can I confirm the block is seated and making proper contact after bolt-down mounting?
With power off, verify each lug screw is torqued firmly on the stripped conductor, then check that the fuse blades sit fully inside the open-design clips with no visible gap.
Does the T60030-2CR ship with Class T fuses or only the block itself?
Only the two-pole fiberglass-reinforced thermoplastic block is included; compatible Class T fuses such as the A6T, JJS, JLLS, LPT or Series T must be purchased separately.