Killark
Killark Y-1M IMC Elbow 1/2 in Threaded Iron Powder Coated Gray
A hazardous-location capped elbow joins two half-inch IMC or threaded rigid conduits with female NPT threads and a powder-coated iron finish
- TypeCable Management & Conduit
- Hazardous-location rated for Class I, II, III Division 1 & 2 environments
- Powder-coated iron construction resists corrosion in harsh industrial settings
- Female-to-female threaded ends connect IMC conduit without adapters
- Compact 2 7/8 in length fits tight conduit runs
- Weighs .79 lb for easy handling and installation
Killark IMC Elbow 1/2 in Threaded
This capped elbow connects two sections of 1/2 inch IMC or threaded rigid conduit in hazardous locations. The female-to-female NPT ends accept standard threaded fittings. It is built from iron with a powder-coated gray finish for corrosion resistance in industrial environments.
Hazardous Location Rating and Durability
The fitting carries Class I Division 1 and 2 ratings for Groups C and D, Class II Division 1 and 2 for Groups E, F, and G, and Class III Division 1 and 2. The powder-coated iron body withstands harsh conditions without active cooling or power requirements.
1/2 in Female NPT Threaded Ends
The decisive specification is the 1/2 inch FNPT by FNPT thread configuration. Buyers needing a different trade size, male threads, or a non-hazardous location fitting must select another product.
Highlights
- Hazardous-location rated for Class I, II, III Division 1 & 2 environments
- Powder-coated iron construction resists corrosion in harsh industrial settings
- Female-to-female threaded ends connect IMC conduit without adapters
- Compact 2 7/8 in length fits tight conduit runs
- Weighs .79 lb for easy handling and installation
Specifications
| Brand | HUBBELL KILLARK |
|---|---|
| Type | Cable Management & Conduit |
Questions about this item
How do I install the Killark Y-1M IMC elbow correctly, and what step do people often miss?
Thread each 1/2 in FNPT end onto IMC or threaded RMC conduit until tight, then apply approved sealant to the joints; the step often missed is using a listed hazardous-location sealing compound to maintain the Class I Division 1 rating.
What maintenance or replacement will this fitting need over time?
The powder-coated iron body resists corrosion, so no routine maintenance is required; replace the elbow only if physical damage, thread wear, or coating breach compromises the hazardous-location seal.
What limit appears first when this elbow is used continuously in a hot, hazardous area?
The 0.79 lb iron casting and powder coating set the thermal and mechanical limit; sustained heat or vibration that degrades the coating or threads will reduce the Class I Division 1 Groups C D integrity before any other factor.