Killark
Killark VSQ6034 60A 600V 3W 4P video accessory
Hazardous-location receptacle rated 60 A, 600 V AC with 3-pole, 4-wire copper-free aluminum construction and padlockable interlock
- TypeHazardous Location
- ColorTransparent
- Rated for hazardous locations with Class I, II, III certifications
- 60 A and 600 V AC capacity for heavy-duty power
- Copper-free aluminium construction resists corrosion in harsh environments
- Padlockable locking handle prevents unauthorised access
- NEMA 3, 4, 4X, 7BCD, 9FG enclosure seals out dust and water
Hazardous-location receptacle for 60 A 600 V
The Killark VSQ6034 is a copper-free aluminum pin-and-sleeve receptacle rated for 60 A at 600 V AC. It provides three poles and four wires in a transparent housing designed for Class I Division 1 and 2 Groups B, C, D and Class II Division 1 and 2 Groups F, G environments. The unit carries NEMA 3, 4, 4X, 7BCD and 9FG enclosure ratings.
Suited for industrial plants needing interlocked
Installations that require a padlockable handle and a mechanical interlock to prevent mating under load will match this specification. Sites that do not need hazardous-location certification, a lower current rating or a non-interlocked connector should consider other product lines.
Interlock and padlockable handle control access
A built-in mechanical interlock blocks insertion or removal while the circuit is energised, and the handle accepts a padlock for lockout procedures. The receptacle is non-fused and includes a disconnect switch, so the single deciding factor is whether the application demands interlocked hazardous-location service at 60 A.
Highlights
- Rated for hazardous locations with Class I, II, III certifications
- 60 A and 600 V AC capacity for heavy-duty power
- Copper-free aluminium construction resists corrosion in harsh environments
- Padlockable locking handle prevents unauthorised access
- NEMA 3, 4, 4X, 7BCD, 9FG enclosure seals out dust and water
Specifications
| Brand | Killark |
|---|---|
| Model | VSQ6034 |
| Type | Hazardous Location |
| Color | Transparent |
Questions about this item
How do I wire the 60 A, 600 V AC receptacle so the mechanical interlock engages before power is applied?
Mount the enclosure, then feed four conductors — three poles plus ground — through the hub and terminate them on the device terminals; the interlock only locks the handle after the plug is fully seated and the handle is thrown, so verify the plug is inserted before closing the cover.
What parts will need replacement after repeated use in a Class I, Division 1 environment?
The copper‑free aluminum housing resists corrosion, but the locking handle, padlock hasp and interior contact surfaces should be inspected annually and replaced if pitting or wear prevents a secure lock.
At what point does the NEMA 3, 4, 4X, 7BCD, 9FG rating limit continuous operation?
The enclosure is rated for those hazardous‑location classes; sustained use is limited by the 60 A current rating and 600 V AC voltage rating — exceeding either will trip upstream protection or overheat the contacts.