Killark VP204513 Pin & Sleeve Plug 200A 4P 4W 600VAC/250VDC
A 200 A, four-pole pin-and-sleeve plug rated 600 V AC and 250 V DC for hazardous locations
- Color MappingGray
- TypeWiring Devices
- 200 A current capacity for heavy-duty power distribution
- 600 V AC and 250 V DC dual voltage rating suits industrial systems
- Class I Division 1/2 Groups A–D rating for hazardous locations
- Copper-free aluminium housing with gray finish resists corrosion
- 4-pole, 4-wire screw-terminal design ensures secure straight connections
Industrial Power Connection
The Killark VP204513 pin-and-sleeve plug delivers a 200 A rating for three-phase circuits at 600 V AC or 250 V DC. It suits heavy-duty industrial equipment that demands a grounded, straight-orientation connection in hazardous Class I Division 1 and 2 locations.
Thermal and Electrical Behaviour
Copper-free aluminium housing resists corrosion while maintaining structural integrity under continuous 200 A loads. Screw-terminal wire connections ensure stable contact resistance, limiting heat rise during normal operation without active cooling.
Hazardous-Location Compliance
The plug meets Class I Division 1 and 2 requirements for Groups A, B, C and D, allowing use where flammable gases or vapours may exist. Grounding Style 1 and a 4.063 in face diameter provide reliable mechanical and electrical mating with matching receptacles.
Highlights
- 200 A current capacity for heavy-duty power distribution
- 600 V AC and 250 V DC dual voltage rating suits industrial systems
- Class I Division 1/2 Groups A–D rating for hazardous locations
- Copper-free aluminium housing with gray finish resists corrosion
- 4-pole, 4-wire screw-terminal design ensures secure straight connections
Specifications
| Brand | HUBBELL KILLARK |
|---|---|
| Color Mapping | Gray |
| Type | Wiring Devices |
Questions about this item
How do I wire the screw terminals on the 200 A 4-pole plug?
Strip each conductor to the length recommended for 200 A screw terminals, insert fully into the four terminal chambers, and torque the screws to the manufacturer’s specified value so no copper strands remain exposed.
What part of the VP204513 plug wears out first and when should I replace it?
The copper-free aluminum housing and gray sleeve should be inspected for corrosion or tracking after each major shutdown; replace the plug if the screw terminals show pitting or the 4.063 in face diameter is deformed.
What thermal or current limit appears first during continuous 200 A three-phase loading?
The 200 A rating at 600 V AC or 250 V DC is the design limit; sustained operation at full load will hit the connector’s temperature rise ceiling before any voltage derating applies.