Killark
Killark OLL-5M LL Conduit Outlet Body 1 1/2in Trade Size 36 cu in
Iron conduit outlet body with 36 cu in capacity and 90-degree LL layout for IMC and RMC raceways
- TypeCable Management & Conduit
- 36 cu in body capacity accommodates larger wire pulls
- LL 90-degree turn routes conduit around corners
- Powder-coated iron resists corrosion in harsh environments
- Threaded 1 1/2 in hub fits IMC and RMC conduit
- Compatible OL-45M cover seals the enclosure securely
Conduit Outlet Body 1 1/2in Trade Size
This Killark conduit outlet body provides a 90-degree directional change for threaded IMC or RMC raceways. The LL body style creates a left-hand turn with a flat back for surface mounting. It is constructed from powder-coated iron for durability in industrial environments.
36 cu in Capacity Practical Limit
The internal volume of 36 cubic inches sets the maximum conductor fill allowed by code for this trade size. Electricians must calculate the total cross-sectional area of all wires passing through to stay within this limit. Exceeding the rated capacity requires a larger body or an additional junction point.
Upgrades From Smaller Trade Sizes
Installations moving from 1 1/4in or smaller conduit gain the larger bending radius and wire-pulling space this 1 1/2in body provides. The jump is worth it when conductor count or insulation thickness makes the previous size non-compliant or difficult to pull. It also accepts the compatible OL-45M cover for enclosure sealing.
Highlights
- 36 cu in body capacity accommodates larger wire pulls
- LL 90-degree turn routes conduit around corners
- Powder-coated iron resists corrosion in harsh environments
- Threaded 1 1/2 in hub fits IMC and RMC conduit
- Compatible OL-45M cover seals the enclosure securely
Specifications
| Brand | HUBBELL KILLARK |
|---|---|
| Type | Cable Management & Conduit |
Questions about this item
Which conduit outlet body capacity suits my pull-box needs?
The OLL-5M provides 36 cu in of internal volume, giving room for splices and bends in 1 1/2 in trade-size conduit runs.
What does the 36 cu in capacity mean when the body is installed?
It allows up to 36 cubic inches of conductor fill, so you can pull and splice multiple IMC or RMC conductors without exceeding NEC box-fill limits.
What connection standard does the 1 1/2 in threaded hub follow, and what conduit types does it accept?
The hub uses standard NPT threads and accepts both IMC and RMC conduit, creating a 90-degree LL turn in hazardous-location systems.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.