Threaded aluminium elbow joins ¾-inch IMC conduit at a 45-degree angle for hazardous-location runs
- TypeCable Management & Conduit
- 45-degree elbow enables smooth conduit routing
- Female-to-male threads allow direct connection
- Aluminium zinc construction resists corrosion
- Hazardous-location rated for Class I, II, III
- Compact 2 3/8 in length fits tight spaces
Hazardous-location conduit elbow
This 45-degree elbow connects 3/4-inch IMC or threaded rigid metal conduit in hazardous areas. The fitting carries Class I Division 1 and 2 Groups C and D, Class II Division 1 and 2 Groups E, F and G, and Class III Division 1 and 2 ratings. Ends are female and male NPT threads for direct coupling. Aluminium construction with powder-coated finish resists corrosion in harsh environments.
Electricians working in classified zones
Installers routing conduit through hazardous locations will find the required ratings and thread profile here. The piece is not suited for non-threaded conduit systems, larger trade sizes or applications that do not demand hazardous-location certification. Buyers needing straight couplings or different bend angles must choose another fitting.
45-degree bend with 3/4-inch NPT threads
The single specification that determines fit is the 45-degree bend combined with 3/4-inch female-to-male NPT threads on IMC or threaded rigid conduit. If the installation calls for a different angle, thread type or trade size, this elbow will not work.
Highlights
- 45-degree elbow enables smooth conduit routing
- Female-to-male threads allow direct connection
- Aluminium zinc construction resists corrosion
- Hazardous-location rated for Class I, II, III
- Compact 2 3/8 in length fits tight spaces
Specifications
| Brand | HUBBELL KILLARK |
|---|---|
| Type | Cable Management & Conduit |
Questions about this item
What is the 45-degree bend radius limit when pulling cable through this elbow?
The 45-degree elbow provides a standard sweep for IMC and threaded RMC conduit; the 2 3/8 in overall length and 2 in height define the physical bend radius for cable pulling.
How much heat does the aluminum body add to a conduit run operating all day?
The powder-coated aluminum construction dissipates heat naturally and adds negligible thermal load to a continuous conduit installation.
Which conduit types must I already have for the 3/4 in FNPT x MNPT ends to connect?
This elbow joins 3/4 in trade size IMC or threaded rigid metal conduit using the female and male NPT threads.