Kidde
Kidde K-270A-SPO Fire Alarm Pull Station
Manual fire alarm pull station with break-glass activation and 150 mm wire leads for flush or surface mounting
- Single-action break-glass operation for reliable alarm initiation
- Six-inch wire leads simplify field wiring on the K-270A series
- Die-cast metal housing withstands heavy use in commercial settings
- Pull force under five pounds meets ADA accessibility requirements
- Designed for both flush and surface mounting in standard boxes
Product Identity
The Kidde K-270A-SPO is a non-coded manual fire alarm pull station built for commercial and institutional facilities. It provides a single-action, break-glass trigger for building fire alarm systems and is intended for professional installation by qualified technicians.
Construction and Wiring
The station uses solid die-cast metal construction with a pull-force under 5 lb to meet ADA requirements. The K-270A series ships with 150mm wire leads for direct field connection, while the base series offers screw terminals. Units mount flush in a standard North American square box with a single-gang plaster cover or surface-mount in a cast, steel, or weatherproof enclosure.
Interface Constraints
The device functions as a simple contact closure — normally open, normally closed, or combination NO/NC — with no built-in signalling protocol or addressable communication. It relies entirely on the host fire alarm control panel for supervision, zone identification, and evacuation logic. Installers must verify panel compatibility and wiring class before deployment.
Highlights
- Single-action break-glass operation for reliable alarm initiation
- Six-inch wire leads simplify field wiring on the K-270A series
- Die-cast metal housing withstands heavy use in commercial settings
- Pull force under five pounds meets ADA accessibility requirements
- Designed for both flush and surface mounting in standard boxes
Specifications
| Brand | KIDDE |
|---|
Questions about this item
Does the K-270A-SPO use screw terminals or wire leads for field connection?
The K-270A Series Manual Stations have 6 inch (150mm) wire leads for field connection.
What type of electrical box is required for flush mounting this pull station?
For flush mounting a 4 inch standard North American square box with single gang plaster cover should be used.
How is the K-270A-SPO activated and what follows?
The station provides a single action, break glass initiating station; pull the lever to break the glass and activate the alarm.