Kensington
Kensington OmniConverter 10T/T1L 10BASE-T to 10BASE-T1L Media Converter 2010000DZ
Converts 10BASE-T Ethernet to 10BASE-T1L single-pair Ethernet using an RJ-45 port and a 2-pin terminal, operating from -40 to 75 °C with wall-mount brackets and a US power supply included
- Converts 10BASE-T to 10BASE-T1L single-pair Ethernet
- Operates from -40 °C to 75 °C for harsh environments
- Wall-mount bracket included for flexible installation
- Certified to UL 62368-1, IEC 62368-1 and CSA 22.2 No. 60950-1
- US power supply and user manual supplied in the box
Single-pair Ethernet converter
The Kensington OmniConverter 10T/T1L bridges standard 10BASE-T networks to 10BASE-T1L single-pair Ethernet. It is built for industrial and building-automation engineers who need to extend Ethernet over long two-wire links without rewiring existing infrastructure.
RJ-45 to two-pin terminal integration
The unit accepts a standard RJ-45 connection on one side and a two-pin T1L terminal on the other, fitting directly onto a DIN rail or wall with the supplied mounting bracket. A US power supply is included so the converter can be powered from local mains without an external PoE source.
Wide-temperature fanless operation
Rated for continuous use from -40 °C to 75 °C, the converter relies on passive cooling and therefore adds no acoustic noise to the environment. Safety certifications include UL 62368-1, UL 60950-1, IEC 62368-1, IEC 60950-1 and CUL CSA C22.2 No. 60950-1.
Highlights
- Converts 10BASE-T to 10BASE-T1L single-pair Ethernet
- Operates from -40 °C to 75 °C for harsh environments
- Wall-mount bracket included for flexible installation
- Certified to UL 62368-1, IEC 62368-1 and CSA 22.2 No. 60950-1
- US power supply and user manual supplied in the box
Specifications
| Brand | Omnitron Systems |
|---|
Questions about this item
What is the maximum operating temperature this media converter can handle in sustained use?
The unit is rated for continuous operation up to 75 °C ambient temperature.
How much heat or noise should I expect when the converter runs all day?
No fan is fitted; the device relies on passive cooling and produces no audible noise during operation.
What power source must I already have on site for this converter to work?
A standard US AC mains outlet is required; the included power supply connects directly to the converter.
Also in this aisle
People compared these