We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Insul-Tube

Insul-Tube Pipe Insulation 1-1/8" ID 3/4" Wall 6 ft Black

SKU CH-6XG3-QFW49

Closed-cell rubber/PVC tube insulates 1-1/8 in. copper pipe, rated -297 to 220 °F with R-5.5 and plenum approval

  • TypeTarps
  • Size3/4"
  • Prevents heat loss with R-value 5.5 insulation
  • Withstands extreme cold down to -297 degrees F
  • Handles high heat up to 220 degrees F
  • Closed-cell foam resists moisture absorption
  • Plenum rated for safe air-handling spaces

Pipe insulation for 1-1/8" copper tube

This closed-cell tube fits 1-1/8 inch inside diameter copper piping and provides a 3/4 inch wall thickness. It is sold in a six-foot length with an unfaced black finish. The product suits HVAC, plumbing and refrigeration lines that need thermal protection.

Operating range from -297 °F to 220 °F

The Buna-N rubber and PVC foam remains flexible across the full temperature span. A flame spread index of 75 and smoke developed index of 100 support plenum-rated installations. The material carries an R-value of 5.5 for consistent thermal resistance.

Replaces worn or missing pipe wrap

Builders use this tube to upgrade bare copper or deteriorated insulation on 3/4 inch pipe size runs. The unslit form requires cutting and sealing on site. It is not suited for applications that demand a pre-slit or self-sealing sleeve.

Highlights

  • Prevents heat loss with R-value 5.5 insulation
  • Withstands extreme cold down to -297 degrees F
  • Handles high heat up to 220 degrees F
  • Closed-cell foam resists moisture absorption
  • Plenum rated for safe air-handling spaces

Specifications

BrandK-FLEX USA
TypeTarps
Size3/4"

Questions about this item

How do I install the unslit tube on an existing pipe?

Slit the 6 ft length lengthwise with a sharp knife, wrap it around the 1 1/8 in copper tube, then seal the seam with compatible adhesive tape or glue.

What maintenance does the closed-cell NBR/PVC foam need over time?

Inspect the 3/4 in wall periodically for tears or UV damage; replace any section where the vapour barrier is broken to keep the R-5.5 value intact.

At what temperature does the insulation reach its upper service limit?

The material is rated to 220 °F maximum operating temperature; sustained exposure above that will degrade the Buna-N rubber/PVC blend.