Ingersoll/Rand
Ingersoll/Rand FA400IG vacuum pump filter 1-1/2" NPT 235 cfm 1 micron
A general-purpose particulate filter with 1-1/2" NPT ports, 235 cfm flow, 1 micron rating, automatic drain and differential pressure indicator
- 1-micron particulate filtration protects downstream equipment
- 235 cfm maximum flow supports high-demand compressed-air systems
- 250 psi operating pressure handles heavy-duty industrial use
- Automatic drain with differential-pressure indicator reduces maintenance effort
- Aluminium bowl and body resist corrosion up to 176 °F
Application
This Ingersoll-Rand FA400IG particulate filter installs in compressed-air lines with 1-1/2 inch NPT connections. It handles up to 235 cfm at 250 psi and 176 Degrees F, capturing particles down to 1 micron. The aluminium bowl includes an automatic drain and a differential pressure indicator for maintenance monitoring.
Who it suits
Workshops and plants that need clean, dry air for pneumatic tools, spray equipment or process lines will benefit from the 235 cfm capacity and 1 micron rating. Operations requiring higher flow, finer filtration or different port sizes should select an alternative model.
Deciding specification
The 1 micron particulate rating determines whether this filter meets your air-quality requirement; if the application demands sub-micron or coalescing performance, a different element is needed.
Highlights
- 1-micron particulate filtration protects downstream equipment
- 235 cfm maximum flow supports high-demand compressed-air systems
- 250 psi operating pressure handles heavy-duty industrial use
- Automatic drain with differential-pressure indicator reduces maintenance effort
- Aluminium bowl and body resist corrosion up to 176 °F
Specifications
| Brand | INGERSOLL-RAND |
|---|
Questions about this item
How long can the filter run at its 235 cfm rating before the pressure drop becomes a problem?
The differential pressure indicator shows when the element is loaded, so you replace it before flow is restricted.
How much heat does the housing add to the compressed-air line during continuous operation?
The aluminium body and bowl run at ambient temperature; the 176 °F limit is the air-stream maximum, not external heat.
What fittings are needed to connect the 1-1/2" NPT ports to existing piping?
Both inlet and outlet use 1-1/2" NPT threads, so standard NPT nipples or unions match directly.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



