Ideal
Ideal 61-176 Isolated Ground Adapter measurement tool
Isolated ground adapter compatible with SureTest circuit analyzers models 61-164 and 61-165, includes cord with NEMA 5-20 plug configuration
- TypeAssortments & Kits
- Isolated ground testing protects sensitive equipment
- Compatible with SureTest circuit analyzers models 61-164 and 61-165
- NEMA 5-20 plug fits 20-amp circuits
- White polyethylene housing resists impact and chemicals
- Includes cord for immediate connection to testers
Ideal 61-176 Isolated Ground Adapter
The Ideal 61-176 is an isolated ground adapter built for electrical testing environments. It connects directly to compatible circuit analyzers to provide a secure ground reference during measurements. The adapter includes a cord and features a NEMA 5-20 plug configuration. Its white polyethylene housing suits professional field use.
Compatible SureTest analyser users
This adapter suits technicians operating Ideal SureTest circuit analysers such as the 61-164 or 61-165 models. It is not intended for general-purpose outlet testing or for use with analysers outside the specified series. Users needing a different plug configuration or a standalone tester should look at other equipment.
NEMA 5-20 plug configuration
The single specification that decides fit is the NEMA 5-20 plug configuration on the included cord. The adapter only functions when the circuit analyser and the supply receptacle both match this exact connector type.
Highlights
- Isolated ground testing protects sensitive equipment
- Compatible with SureTest circuit analyzers models 61-164 and 61-165
- NEMA 5-20 plug fits 20-amp circuits
- White polyethylene housing resists impact and chemicals
- Includes cord for immediate connection to testers
Specifications
| Brand | Ideal |
|---|---|
| Type | Assortments & Kits |
Questions about this item
How do I install the 61-176 adapter on a SureTest 61-164 or 61-165 circuit analyzer, and what step is often missed?
Plug the adapter cord into the analyzer's NEMA 5-20 receptacle and verify the isolated ground indicator lights; the step often missed is confirming the indicator before testing.
What maintenance or replacement will the 61-176 adapter need after extended use?
Inspect the polyethylene housing and cord for cracks or discoloration; replace the adapter if the isolated ground indicator fails to illuminate during a known-good circuit test.
What limit appears first when the 61-176 adapter is used continuously on a 20 A circuit?
The NEMA 5-20 rating limits continuous current to 20 A; exceeding this will trip the upstream breaker before the adapter itself fails.