Hubbell Incorporated
Hubbell Incorporated RACO 697 3-Gang Masonry Electrical Box 67.3 cu in
A three-gang masonry box with 67.3 cu in capacity, welded steel construction and nineteen concentric knockouts
- TypeElectrical Boxes & Covers
- Large 67.3 cu. in. capacity gives extra wiring room
- Welded steel construction stays rigid during masonry work
- Nineteen 1/2 & 3/4 in. concentric knockouts simplify cable entry
- Device ears block mortar from reaching mounting holes
- Fits 6, 8 and 10 in. block walls for versatile installs
3-Gang Masonry Box for Block Walls
This three-gang masonry electrical box provides 67.3 cu. in. of internal volume for wiring in concrete or block construction. It is built for 6, 8, and 10 in. block walls and accepts standard wall plates with 6-32 tapped device holes. The welded steel body will not fall apart during installation.
Rugged Welded Construction and Knockout Layout
Nineteen concentric 1/2 in. and 3/4 in. knockouts give multiple entry options without extra drilling. Device ears inside the box keep mortar out of the mounting holes while work progresses. The rectangular shape matches square cuts in block for a clean fit.
Partition Compatibility and Gang Range
Steel voltage partition 971 fits this 3-1/2 in. deep box to separate circuits when required. The same design is available from one to six gangs in both 2-1/2 in. and 3-1/2 in. depths for consistent rough-in across a project.
Highlights
- Large 67.3 cu. in. capacity gives extra wiring room
- Welded steel construction stays rigid during masonry work
- Nineteen 1/2 & 3/4 in. concentric knockouts simplify cable entry
- Device ears block mortar from reaching mounting holes
- Fits 6, 8 and 10 in. block walls for versatile installs
Specifications
| Brand | RACO |
|---|---|
| Type | Electrical Boxes & Covers |
Questions about this item
How is the RACO 697 box secured inside a masonry block wall, and what step do installers often miss?
The rectangular box fits a square cut in 6, 8 or 10 in. block walls; the step often missed is fitting the steel voltage partition #971 before pulling wires so low-voltage and power circuits stay separated.
What part of the RACO 697 box will need attention or replacement after the wall is finished?
The 19 concentric 1/2 & 3/4 in. knockouts are removed once; the remaining 6-32 tapped device ears and welded steel body require no maintenance, only standard wall plates for cover.
What capacity limit of the 67.3 cu. in. box is reached first when multiple circuits are pulled through?
The 67.3 cu. in. volume fills quickly with three gangs of devices and 19 conduit entries; the cubic-inch limit is reached before the 6-32 mounting holes or knockout count become constraints.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thomas & Betts TY523M Cable Tie 18lb 4in Natural Nylon Stainless Steel Locking Clip Pack 100
CALBRITE S60700FDCC Weatherproof Electrical Box 5.90" x 2.83" 25 cu in
- Electrical Boxes &…
HOFFMAN A12P10G Interior Panel Steel 10.75in H 8.88in W 14 Gauge
- Electrical Boxes &…