Hubbell Incorporated
Hubbell Incorporated RACO 3008 IMC Rigid Grounding Connector 2 in Set Screw Steel Zinc Plated
Steel zinc-plated set-screw connector joins 2 in IMC or rigid conduit, UL 514B listed and concrete-tight
- Color MappingGray
- TypeCable Management & Conduit
- UL 514B listed for code compliance
- 2-inch trade size fits IMC and RMC conduit
- Set-screw connection installs without threading tools
- Zinc-plated steel resists corrosion in damp locations
- Concrete-tight rating protects conductors in slab pours
RACO 3008 Grounding Connector
The RACO 3008 is a steel set-screw connector designed for 2-inch IMC and rigid metal conduit. It provides a secure mechanical connection and grounding path for electrical installations in commercial and industrial environments. The zinc-plated finish offers corrosion resistance for long-term durability. UL 514B listing confirms compliance with safety standards for conduit fittings.
Sustained Load Performance
The connector maintains a reliable grounding bond and mechanical grip under continuous vibration and thermal cycling typical of rigid conduit runs. Its concrete-tight rating ensures the connection remains intact when embedded in poured concrete. The set-screw design resists loosening over time without requiring periodic re-torquing. Steel construction withstands physical stress during wire pulling and system expansion.
Deciding Specification
The trade size of 2 inches and compatibility with IMC and RMC conduit types determine if this fitting matches the raceway system. The male NPS thread and set-screw connection method must align with the installation requirements. Buyers needing a different conduit size, compression coupling, or insulated throat cannot use this part.
Highlights
- UL 514B listed for code compliance
- 2-inch trade size fits IMC and RMC conduit
- Set-screw connection installs without threading tools
- Zinc-plated steel resists corrosion in damp locations
- Concrete-tight rating protects conductors in slab pours
Specifications
| Brand | RACO |
|---|---|
| Color Mapping | Gray |
| Type | Cable Management & Conduit |
Questions about this item
How much heat does the RACO 3008 generate during continuous operation?
This grounding connector is a passive steel fitting with no electrical load, so it produces no measurable heat while installed.
What conduit and tools are required to install the RACO 3008?
You need 2 in IMC or RMC conduit, a compatible set-screw driver or wrench, and standard conduit-cutting tools for unthreaded rigid metal conduit.
Will the RACO 3008 connect to older rigid conduit already in the walls?
Yes, it fits 2 in trade-size IMC and RMC, including unthreaded RMC, and its NPS male threads match legacy conduit of the same trade size.