We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Hubbell Incorporated

Hubbell Incorporated GFRTW15W GFCI Receptacle 15A 125VAC 5-15R

SKU CH-TFPN-M4PWH

Provides 15 A, 125 V ground-fault protection with continuous self-testing every 30 seconds and tamper-resistant shutters

  • TypeWiring Devices
  • AUTOGUARD self-test checks protection every 30 seconds
  • Patented shutter blocks foreign objects for tamper resistance
  • Meets NEC 517-18c TR and 406.9 WR requirements
  • UV and corrosion resistant for harsh damp locations
  • Prevents power to face if line and load reversed

Hubbell AUTOGUARD GFCI Receptacle 15A

This 15A 125VAC 5-15R receptacle provides ground-fault protection for residential and light-commercial circuits. It suits electricians and facility managers who need code-compliant protection in damp or harsh locations. The device integrates tamper-resistant shutters and weather-resistant construction to meet NEC requirements for TR and WR applications. It is not intended for buyers who need higher amperage ratings or industrial pin-and-sleeve configurations.

Self-test monitoring and visual indicators

Patented AUTOGUARD technology performs automatic self-tests every 30 seconds to verify protection capability continuously. Clear face indicators show power status, trip condition, ground-fault condition and end-of-life status at a glance. If critical components fail or line and load conductors are reversed, power is denied to the receptacle face and downstream outlets. No thermal, noise or power-draw data is provided for this passive wiring device.

Sustained protection under fault conditions

The self-test cycle runs continuously rather than only during a brief power-up check, so protection integrity is verified throughout the service life. Reverse-wiring lockout remains active whenever the device is energised, preventing energised faces after misinstallation. UV and corrosion resistance maintain enclosure integrity in damp environments over extended periods. The product ships new and complies with the 2015 UL 943 GFCI safety standard.

Highlights

  • AUTOGUARD self-test checks protection every 30 seconds
  • Patented shutter blocks foreign objects for tamper resistance
  • Meets NEC 517-18c TR and 406.9 WR requirements
  • UV and corrosion resistant for harsh damp locations
  • Prevents power to face if line and load reversed

Specifications

BrandHUBBELL WIRING DEVICE-KELLEMS
TypeWiring Devices

Questions about this item

How do I wire the Hubbell GFRTW15W and which mistake trips the line-load reversal protection?

Connect the supply conductors to the LINE terminals and downstream wiring to the LOAD terminals; if line and load are swapped, the AUTOGUARD® self test denies power to the receptacle face and downstream outlets.

What ongoing checks does the GFRTW15W perform and when does it indicate end of life?

The AUTOGUARD® self test runs automatically every 30 seconds; a visual indicator on the device face shows end-of-life status when protection capability is lost.

At what current does the GFRTW15W trip during a sustained ground fault?

The receptacle is rated 15 A at 125 VAC and complies with the UL 943 Class A trip threshold of 4 to 6 mA for personnel protection.