Hubbell Incorporated
Hubbell Incorporated EL218S3/8L3KUV/BL 10W 3000K dlp replacement lamp
LED floodlight delivers 1078 lumens at 3000 K while drawing 10 W from 120-277 V AC
- TypeTraffic & Parking Lot
- Weight3.25
- 10 W LED replaces 75 W halogen for lower energy use
- 1 078 lumens at 3000 K delivers warm, bright illumination
- CRI 72 provides acceptable colour rendering for outdoor areas
- 120–277 V AC input suits standard North American supplies
- Die-cast aluminium housing with 1/2 in NPS knuckle mount for secure ground installation
10 W LED floodlight for ground mounting
This 10 W LED floodlight replaces a 75 W halogen lamp and delivers 1,078 lumens at 3000 K with a CRI of 72. The die-cast aluminium housing is finished in black and mounts via a 1/2 in NPS thread knuckle for ground installation. It operates on 120 to 277 V AC without an integrated sensor.
NEMA 3x3 distribution shapes the beam
The NEMA 3x3 light distribution pattern focuses output into a defined spread suited to parking-lot and traffic-area lighting. No sensor is included, so the fixture remains on whenever power is applied unless an external control is added. The fixed colour temperature and CRI are set by the integrated LED module.
Simple knuckle mount on 120–277 V supply
Installation consists of threading the 1/2 in NPS knuckle onto a compatible mounting arm or junction box and connecting the supply wires to a 120–277 V AC circuit. The unit weighs 3.25 lb, so the mounting structure must support that load. Common issues include overlooking the lack of a built-in photocell and using a supply voltage outside the rated range.
Highlights
- 10 W LED replaces 75 W halogen for lower energy use
- 1 078 lumens at 3000 K delivers warm, bright illumination
- CRI 72 provides acceptable colour rendering for outdoor areas
- 120–277 V AC input suits standard North American supplies
- Die-cast aluminium housing with 1/2 in NPS knuckle mount for secure ground installation
Specifications
| Brand | HUBBELL LIGHTING - KIM |
|---|---|
| Type | Traffic & Parking Lot |
| Weight | 3.25 |
Questions about this item
Will the LED module in this EL218S3/8L3KUV/BL floodlight need to be replaced separately down the road?
The LED light engine is integrated into the die-cast aluminium housing and is not designed as a user-serviceable module, so the entire fixture would be replaced at end of life.
What limits continuous operation of this 10 W LED floodlight first — thermal protection or driver circuitry?
The unit runs on 120 to 277 V AC with a 10 W LED load and no active cooling; thermal management relies on the die-cast aluminium housing, so sustained high ambient temperature is the practical limit.
How much audible noise or heat does the fixture produce when it runs all day?
With no fan or moving parts the floodlight operates silently, and the 10 W LED load means the die-cast aluminium housing becomes warm but not excessively hot during continuous use.