Hubbell Incorporated
Hubbell Incorporated AP2I Abandonment Plate 1 Gang PVC Ivory
A single-gang ivory PVC abandonment plate for covering unused electrical boxes in rated floor assemblies
- TypeElectrical Boxes & Covers
- ColorIvory
- One-gang abandonment plate covers unused openings
- Ivory PVC construction resists corrosion and impact
- Smooth finish blends with existing wall surfaces
- UL 514 listed for fire-rated floor assemblies
- Suitable for concrete and steel floor installations
Purpose and Fit
This abandonment plate covers a single-gang opening in concrete or steel floor units that have a concrete topping. It is intended for installers who need to close an unused device box while maintaining the floor’s fire rating of one to four hours for concrete or one to three hours for steel assemblies. The ivory PVC finish matches common interior trim.
Thermals Noise and Power
The plate is a passive component with no electrical load, so it produces no heat, draws no power and makes no sound. Its smooth PVC surface simply seals the opening against air movement and debris. Compliance with UL 514 confirms that the assembly retains its rated fire resistance when this cover is installed.
Build Quality and Connections
Moulded from PVC with a smooth ivory finish, the round plate measures three inches across and fits a standard one-gang box. The material resists impact and moisture in floor environments. Mounting hardware is not included, so the installer supplies screws appropriate for the box type. The cover sits flush once secured, leaving a clean, low-profile surface.
Highlights
- One-gang abandonment plate covers unused openings
- Ivory PVC construction resists corrosion and impact
- Smooth finish blends with existing wall surfaces
- UL 514 listed for fire-rated floor assemblies
- Suitable for concrete and steel floor installations
Specifications
| Brand | HUBBELL WIRING DEVICE-KELLEMS |
|---|---|
| Type | Electrical Boxes & Covers |
| Color | Ivory |
Questions about this item
How do I install the AP2I abandonment plate on a concrete floor, and what step is often missed?
Mount the 1-gang PVC plate over the existing opening using the UL 514-listed hardware; the step often missed is confirming the floor assembly carries a 1- to 4-hour fire rating before installation.
What maintenance or replacement will the ivory PVC abandonment plate need over time?
The smooth PVC finish resists corrosion, so no routine maintenance is required; replace the plate only if physical damage occurs or if the floor's fire rating changes.
What limit appears first when the plate is exposed to sustained heat in a fire-rated floor?
The plate is listed to UL 514 for use in 1- to 4-hour rated concrete or 1- to 3-hour rated steel floors with concrete topping; the fire rating of the floor assembly is the limiting factor.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.