Hubbell Incorporated
Hubbell Incorporated 074-09-3543 90 Degree Liquid-Tight Conduit Fitting
A 90-degree liquid-tight conduit fitting in steel for 3/4-inch trade size, connecting flexible metallic or non-metallic conduit with insulated box connection and stainless-steel mesh.
- TypeCable Management & Conduit
- ColorGray
- 90-degree angle routes conduit in tight spaces
- Steel construction resists impact and corrosion
- Gray finish blends with standard installations
- Insulated throat protects conductors from sharp edges
- Suitable for hazardous locations Class I Div 2 and Class II Div 1 and 2
90-Degree Liquid-Tight Fitting
This steel conduit fitting connects flexible metallic or non-metallic liquid-tight conduit at a 90-degree angle. It suits electricians and installers routing cable into enclosures where a straight entry will not fit. The 3/4 inch trade size matches standard knockouts and hubs.
Thermals Noise Power
As a passive mechanical component the fitting generates no heat, produces no audible noise and draws no electrical power. Its stainless-steel mesh and insulated throat protect conductors from abrasion and moisture without active cooling or energy consumption.
Hazardous-Location Rating
The fitting carries Class I Division 2, Class II Divisions 1 and 2, and Class III Divisions 1 and 2 ratings, allowing use in defined hazardous areas where standard fittings are not permitted. Gray steel construction resists corrosion in damp or chemical environments.
Highlights
- 90-degree angle routes conduit in tight spaces
- Steel construction resists impact and corrosion
- Gray finish blends with standard installations
- Insulated throat protects conductors from sharp edges
- Suitable for hazardous locations Class I Div 2 and Class II Div 1 and 2
Specifications
| Brand | HUBBELL WIRING DEVICE-KELLEMS |
|---|---|
| Type | Cable Management & Conduit |
| Color | Gray |
Questions about this item
How do I install the 90-degree liquid-tight conduit fitting on 3/4 in trade size conduit and what step is often missed?
Thread the 3/4 in MNPT box connection into the enclosure, insert the conduit until it seats fully, then tighten the gland nut to compress the stainless steel mesh grip; the step often missed is fully seating the conduit before final tightening.
What maintenance or replacement will the Hubbell 074-09-3543 fitting need over time?
Inspect the gray steel body and stainless steel mesh for corrosion or damage after exposure to moisture or chemicals; replace the fitting if the liquid-tight seal is compromised or the mesh shows wear.
What is the first limit that appears when the fitting is used continuously in a Class I Div 2 hazardous location?
The fitting's hazardous location rating for Class I Div 2, Class II Div 1 and 2, and Class III Div 1 and 2 defines the environmental limit; sustained use beyond those classified conditions is the first constraint.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.