HP
HP 1000 W Hot-Swap Redundant Server Power Supply 399771-001
A 1000-watt hot-swap redundant power supply for ProLiant ML350, ML370, DL380 G5 and DL385 G2 servers
- 1000 W output powers demanding ProLiant servers
- Hot-swap redundant design keeps systems running during module replacement
- Wide AC 90 – 264 V input suits global power environments
- Compatible with ML350, ML370, DL380 G5 and DL385 G2 models
- Light 2.0 lb unit eases installation and maintenance
1000 W Hot-Swap Server Power Supply
This HP power supply delivers 1000 W of redundant AC power for ProLiant ML350, ML370, DL380 G5 and DL385 G2 servers. It accepts a wide AC 90-264 V input range at 50/60 Hz. The unit is designed for hot-swap installation in compatible server chassis. New condition, manufacturer model 7001044-Y001, weighs 2.0 pound.
Suited for ProLiant G5 and G2 server maintenance
This unit fits administrators replacing a failed module in the listed ProLiant models or adding a second module for N+1 redundancy. Builders working on newer ProLiant generations, non-HP server platforms, or workstations requiring different form factors or wattage ratings should look at other parts.
1000 W output capacity
The single specification that determines fit is the 1000 W output rating matched to the server's power budget and redundant configuration requirements. Verify the target server model appears in the supported list — ML350, ML370, DL380 G5 or DL385 G2 — before purchase.
Highlights
- 1000 W output powers demanding ProLiant servers
- Hot-swap redundant design keeps systems running during module replacement
- Wide AC 90 – 264 V input suits global power environments
- Compatible with ML350, ML370, DL380 G5 and DL385 G2 models
- Light 2.0 lb unit eases installation and maintenance
Specifications
No published specifications for this item yet.
Questions about this item
Which ProLiant server models accept the 399771-001 1000-Watt hot-swap power supply?
The unit fits ProLiant ML350, ML370, DL380 G5 and DL385 G2 servers.
What is the correct sequence for hot-swapping this redundant PSU without interrupting power?
Leave the mate supply running, release the latch, slide the old unit out, push the replacement in until the latch clicks, then verify the green LED.
When should the internal fan assembly be inspected or replaced on a 1000-Watt HP redundant supply?
Check fan noise and airflow at each planned service interval; replace the fan module if bearing noise appears or airflow drops below spec.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Sunfounder Raspberry Pi Ultimate Kit with PiCrawler AI Robot 337 components 131 projects
minisforum MF-SRP01 SSD Heatsink accessories barebone
- SSD Heatsink