Hayward Flow Control
Hayward Flow Control WCV1300V Wafer Check Valve 2.4063 in
Inline wafer check valve with PVC body, FPM seals and 316 stainless steel spring for 3-inch flange connections, rated to 150 psi at 70 °F and operational between 40 °F and 140 °F
- Inline wafer design simplifies installation between flanges
- PVC body resists corrosion in water systems up to 150 psi
- Single-disc flow path reduces turbulence and pressure drop
- 316 stainless steel spring ensures reliable closure at 1 psi cracking pressure
- FPM seals withstand temperatures from 40 to 140 degrees F
Wafer Check Valve 2.4063 in
The Hayward Flow Control WCV1300V is a new inline wafer check valve constructed from PVC with FPM seals and a 316 stainless steel spring. It connects via flange x flange fittings to suit a 3 in pipe size and operates in horizontal or vertical orientations. The unit opens with a cracking pressure of 1 psi and handles water service up to 150 psi at 70 Degrees F.
Suitable for water lines needing a compact
This valve fits systems where a short face-to-face wafer design is preferred between flanges and the media temperature stays between 40 and 140 Degrees F. It is not intended for steam service, applications exceeding the stated pressure or temperature limits, or installations requiring a different pipe diameter or connection style.
2.4063 in overall length decides fit
The overall length of 2.4063 in determines whether the valve sits correctly within the available flange gap on the pipeline. Verify this dimension against the installed space before ordering to avoid assembly issues.
Highlights
- Inline wafer design simplifies installation between flanges
- PVC body resists corrosion in water systems up to 150 psi
- Single-disc flow path reduces turbulence and pressure drop
- 316 stainless steel spring ensures reliable closure at 1 psi cracking pressure
- FPM seals withstand temperatures from 40 to 140 degrees F
Specifications
| Brand | HAYWARD FLOW CONTROL |
|---|
Questions about this item
Does the 1 psi cracking pressure create noise or heat during continuous flow?
The valve opens at 1 psi and uses a 316 stainless-steel spring, so it operates silently with no heat generated during all-day service.
What flange size and seal material must my piping already have for this wafer check valve?
It fits 3-inch flange-to-flange connections and requires FPM seals on both faces to seal properly.
Will the PVC body and FPM seals handle the 140 °F water from my existing boiler loop rated at 150 psi?
Yes, the valve is rated for 150 psi at 70 °F and a maximum temperature of 140 °F, matching those conditions.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor 70204 Acrylic Coated Polyester Gray Hot Shot BoatGuard Boat Cover
- Transparent
BoatBuckle F12071 Kwik-Lok Gunwale Tie-Down Stainless Steel
- Transparent



