Hayward Flow Control
Hayward Flow Control TBH2050ASTE0000 Ball Valve 1/2 in CPVC/EPDM
A manual two-way ball valve with CPVC body and EPDM seals for corrosive chemicals and water, full-port design and locking tee handle rated to 250 psi
- True union design simplifies maintenance and replacement
- CPVC body and ball resist corrosive chemicals and water
- Full port ball allows unrestricted flow through the valve
- Locking tee handle prevents accidental operation during service
- Rated for 250 psi maximum operating pressure
Manual CPVC Ball Valve
The Hayward Flow Control TBH2050ASTE0000 is a manual two-way ball valve built for corrosive chemical and water lines. Its CPVC body and full-port CPVC ball handle media up to 250 psi in straight three-piece construction. The half-inch true-union ends suit process piping where frequent disassembly is needed.
Locking Tee Handle
A locking tee handle prevents accidental operation and allows padlocking in the open or closed position. The true-union design lets technicians remove the centre section without disturbing the surrounding pipework, reducing downtime during seal replacement or inspection. No actuator or automation kit is included.
Simple Union Installation
The valve threads into standard half-inch CPVC unions using solvent cement or compatible thread sealant. Over-tightening the union nuts can crack the CPVC hubs, so hand-tight plus a quarter turn is typical. The three-piece body bolts must be re-torqued evenly after the first pressure cycle to avoid weeping at the body joints.
Highlights
- True union design simplifies maintenance and replacement
- CPVC body and ball resist corrosive chemicals and water
- Full port ball allows unrestricted flow through the valve
- Locking tee handle prevents accidental operation during service
- Rated for 250 psi maximum operating pressure
Specifications
| Brand | HAYWARD FLOW CONTROL |
|---|
Questions about this item
Will the CPVC ball or EPDM seals need periodic replacement?
The CPVC ball and EPDM seats resist corrosive chemicals and water, so they last through normal service without a scheduled change interval.
What pressure limit is reached first during continuous operation?
The valve is rated for a maximum operating pressure of 250 psi, which is the primary limit under sustained use.
Does the valve generate noticeable heat or noise when left open all day?
As a manual quarter-turn valve with no moving actuator, it produces no heat or noise of its own during continuous flow.