GE THQL32060 60A 3 Pole 120/240V 10kAIC Q-Line Circuit Breaker
A 60 A three-pole plug-in breaker rated 120/240 V AC with a 10 kA interrupting capacity for Power Mark Gold and AQ load centres
- TypeCircuit Breakers
- Three-pole design protects all phases in a 120/240 V system
- 60 A rating handles substantial residential and light-commercial loads
- 10 kA interrupting capacity clears faults safely
- Plug-in mounting fits Power Mark Gold and AQ panels
- Compact 3.3 in length saves space in crowded load centres
Three-Pole 60 A Protection
The GE THQL32060 is a 60 A three-pole Q-Line circuit breaker rated for 120/240 V AC with a 10 kAIC interrupting rating. It uses a toggle actuator and plug-in mounting for compatible load centres. The breaker occupies a 100 A frame size and provides standard overcurrent protection for three-phase panels.
Panel Integration Requirements
This breaker plugs directly into Power Mark Gold load centres and AQ lighting panels that accept the THQL series. It requires a panelboard with three available pole spaces and lug terminals sized for the 100 A frame. The plug-in design frees the installer from bolt-on hardware and speeds up panel assembly.
Upgrade From Lower-Rated Breakers
Replacing a lower-amperage three-pole breaker with this 60 A unit adds capacity for larger three-phase loads while staying within the same frame footprint. The jump is worth it when the existing breaker trips under normal demand and the panel bus rating supports the higher setting. It does not suit DC circuits or panels outside the AQ and Power Mark Gold series.
Highlights
- Three-pole design protects all phases in a 120/240 V system
- 60 A rating handles substantial residential and light-commercial loads
- 10 kA interrupting capacity clears faults safely
- Plug-in mounting fits Power Mark Gold and AQ panels
- Compact 3.3 in length saves space in crowded load centres
Specifications
| Brand | General Electric |
|---|---|
| Model | THQL32060 |
| Type | Circuit Breakers |
Questions about this item
Will the 60 A rating hold continuously or does the breaker trip early on a long motor start?
The breaker carries 60 A continuously per its standard rating; sustained overloads above that level will trip it according to the thermal-magnetic curve.
How much heat does the THQL32060 add to a panel that runs all day?
Normal operation at rated load produces modest warmth; the 100 A frame and plug-in mount dissipate heat into the Power Mark Gold bus without forced cooling.
Which load-center series must already be installed for this breaker to fit?
It plugs directly into GE Power Mark Gold load centers and AQ lighting panels that accept the Q-Line frame.