GE
GE THQC2115WL 15A 2 Pole 120/240V AC Miniature Circuit Breaker
A 15 A, two-pole miniature breaker rated for 120/240 V AC panels with a 10 kA interrupting capacity
- 15 A protection for residential circuits
- 10 kA interrupting capacity at 120/240 V AC
- Two-pole design serves 120/240 V single-phase panels
- UL listed for use with GE panelboards
- Surface or DIN-rail mount fits standard enclosures
GE THQC2115WL 15A 2-Pole Breaker
The GE THQC2115WL is a miniature circuit breaker rated at 15 amps and 120/240V AC. It belongs to the THQC series and uses a two-pole configuration for single-phase panels. The toggle actuator provides manual switching and trip indication. It is designed for surface or DIN rail mounting inside compatible GE panelboards.
For GE panelboard circuits needing 15A protection
This breaker suits electricians and facility managers protecting 15-amp branch circuits in GE load centres. The lug terminals accept copper wire from 14 AWG to 8 AWG and aluminium wire from 12 AWG to 8 AWG. It is not for applications requiring a DC voltage rating. Buyers needing a different amperage, pole count, or a breaker for another panelboard brand should look elsewhere.
10kA interrupting rating at 120/240V AC
The maximum AIR rating of 10kA at 120/240V AC determines whether this breaker can safely clear a fault on the supply side. The frame size is 100A and the unit carries a UL Listing. Verify that the available fault current at the installation point does not exceed this rating before specifying the device.
Highlights
- 15 A protection for residential circuits
- 10 kA interrupting capacity at 120/240 V AC
- Two-pole design serves 120/240 V single-phase panels
- UL listed for use with GE panelboards
- Surface or DIN-rail mount fits standard enclosures
Specifications
| Brand | GE |
|---|
Questions about this item
Will the GE THQC2115WL fit in my existing GE panelboard without modifications?
Yes, it is built for GE panelboards and mounts on surface or DIN rail, so it fits the same footprint as other THQC breakers in that series.
How can I verify the 15 A breaker trips correctly after installation?
Switch the toggle to ON, apply a known load up to 15 A, and confirm the breaker holds; then exceed 15 A briefly to see the toggle move to the tripped position.
Does the box include the lug terminals and mounting hardware, or must I buy them separately?
The breaker ships with integral lug terminals that accept 14–8 AWG copper or 12–8 AWG aluminium; no separate lugs or mounting brackets are required for standard surface or DIN rail installation.