GE
GE THQB2135 Miniature Circuit Breaker 35A 2 Pole 120/240V AC
A 35 A, two-pole miniature breaker rated 120/240 V AC with a 10 kA interrupting capacity and bolt-on mounting for load centers
- 35 A two-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating clears faults safely
- Bolt-on mounting fits THQ load centers and panels
- Terminal lugs accept 8 to 3 AWG conductors
- Compact 3.5 × 1 × 3.3 in frame saves panel space
35 A two-pole breaker for lighting panels
The GE THQB2135 is a 35 A miniature circuit breaker built for single-phase lighting panels and load centres. It uses a bolt-on mounting style and accepts wire from 8 AWG to 3 AWG through lug terminals. The unit is UL Listed and rated for 120/240 V AC operation.
Sustained 35 A protection with 10 kA interrupting
Under continuous load the breaker carries its full 35 A rating without nuisance tripping. The thermal-magnetic mechanism responds to prolonged overloads while the 10 kA AIR rating at 120/240 V AC ensures safe interruption of high fault currents. Toggle actuation provides clear on/off status during maintenance.
100 A frame size decides panel compatibility
The breaker fits THQB-series load centres built on a 100 A frame. Its 3.5 in length, 1 in width and 3.3 in depth match the series mounting footprint. Panels with a different frame size or plug-on bus arrangement will not accept this bolt-on device.
Highlights
- 35 A two-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating clears faults safely
- Bolt-on mounting fits THQ load centers and panels
- Terminal lugs accept 8 to 3 AWG conductors
- Compact 3.5 × 1 × 3.3 in frame saves panel space
Specifications
| Brand | GE |
|---|
Questions about this item
How much heat does the 35A THQB breaker generate during continuous all-day operation?
The 35A rating and 10kA interrupting capacity at 120/240V AC define its electrical limits; heat rise stays within UL Listed limits for a 100A frame bolt-on breaker in a lighting panel.
What panel or load center is required to mount this bolt-on two-pole breaker?
It fits GE lighting panels or load centers that accept THQB series bolt-on breakers in a 100A frame size, using the supplied lug terminals for 8 to 3 AWG wire.
Will this 35A two-pole breaker coordinate with older 100A frame GE breakers already in my panel?
Yes, it shares the THQB 100A frame dimensions and bolt-on mounting, so it installs alongside existing GE breakers of the same series in compatible load centers.