GE THQB 35 A 1 Pole Bolt On Circuit Breaker 120/240V AC
A 35 A single-pole bolt-on breaker rated for 120/240 V AC with a 10 kA interrupting capacity
- TypeCircuit Breakers
- 35 A rating protects 120/240 V circuits
- 10 kA interrupting capacity clears faults safely
- Bolt-on mounting fits compatible load centres
- Single-pole design suits standard lighting panels
- UL Listed for code-compliant installations
Circuit Breaker for Lighting Panels and Load Centers
This GE THQB miniature circuit breaker provides 35 A overcurrent protection for single-phase 120/240 V AC circuits. It mounts by bolt-on connection in compatible GE lighting panels and load centers with a 100 A frame size.
Suited for Single-Phase Branch Circuits Requiring
Install this breaker when a 35 A single-pole device is specified for a lighting or appliance branch circuit. It is not suitable for circuits requiring two-pole or three-pole protection, DC voltage applications, or higher interrupting ratings beyond 10 kA at 120/240 V AC.
10 kA Interrupting Rating at 120/240 V AC
The breaker carries a maximum AIR rating of 10 kA at the rated voltage, which determines whether it meets the available fault current at the installation point. Verify the panel’s short-circuit current rating before selection.
Highlights
- 35 A rating protects 120/240 V circuits
- 10 kA interrupting capacity clears faults safely
- Bolt-on mounting fits compatible load centres
- Single-pole design suits standard lighting panels
- UL Listed for code-compliant installations
Specifications
| Brand | GE |
|---|---|
| Type | Circuit Breakers |
Questions about this item
What panel space does the 1.0 in width breaker require for bolt-on mounting?
The single-pole unit measures 1.0 in wide, 3.53 in long and 3.28 in deep, so reserve that exact slot in a compatible load center or lighting panel.
Which torque value should I apply when securing the bolt-on lugs to avoid a loose connection?
Insert the breaker onto the panel bus, tighten the mounting bolts to the manufacturer-specified torque for the frame, then torque the terminal lugs within the 14 MCM Cu to 8 MCM wire range.
When should the 35 A device be replaced after a fault event?
Replace the breaker if it has interrupted a short-circuit at or near its 10 kA AIR rating, shows contact discoloration, or fails to hold the 35 A load without nuisance tripping.